首页> 外文期刊>Clinical ophthalmology >Tear Film Characteristics During Wear of Daily Disposable Contact Lenses
【24h】

Tear Film Characteristics During Wear of Daily Disposable Contact Lenses

机译:日常一次性隐形眼镜磨损过程中的撕膜特性

获取原文
           

摘要

Purpose: To evaluate changes induced over time by three daily disposable (DD) contact lenses on tear meniscus height (TMH), pre-lens non-invasive break-up time (pre-lens NIBUT), tear film osmolarity (TO) and objective quality of vision (OQV). Patients and Methods: Forty-six subjects enrolled in this prospective open-label unmasked non-randomized simultaneous comparative cross-over study. For the first week of the study, subjects wore a nesofilcon A lens in the right eye and a delefilcon A lens in the left eye. After 3 days of washout, for the second week, subjects wore a nesofilcon A lens in the left eye and a stenfilcon A lens in the right eye. TMH, pre-lens NIBUT, TO and OQV were measured before contact lens fitting and for each contact lens combination on day 1 at 20 minutes and on day 7 after ≥ 8 hours of wear. OQV measurement included the changes of objective scatter index (OSI), the stability index (SI) and the fluctuation index (FI) calculated in a range of time of 20 s from a blink. Results: TMH was unchanged at 20 minutes wear of all lenses but was significantly reduced after 8 or more hours wear (on day 7) of delefilcon A and stenfilcon A, respectively. Pre-lens NIBUT was significantly reduced with all lenses, while no significant change in TO was observed with any lens. SI and FI increased significantly for all lenses at both wear times. Conclusion: While the presence of any contact lens on the eye challenges the tear film, nesofilcon A contact lenses, despite their high water content, compared to delefilcon A and stenfilcon A contact lenses, showed a lower overall effect. We speculate that superior tear film behavior while wearing nesofilcon A lenses may translate to improved subjective comfort, but this remains to be evaluated.
机译:目的:为了评估随着时间的推移诱导的变化,通过三次每日一次性(DD)隐形眼镜在泪圈高度(TMH),预透镜非侵入性分解时间(镜头滴注前),泪膜渗透压(至)和目标愿景质量(OQV)。患者和方法:招收46名受试者,参加这一预期开放标签未掩蔽的非随机性同时对比交叉研究。对于研究的第一周,受试者在右眼上戴上Nesofilcon透镜,左眼透镜是Delefilcon。 3天后的冲洗后,第二周,受试者在左眼中戴上NESOFILCON A晶状体,右眼透镜透镜。在接触式镜片拟合之前测量TMH,镜头前NiBut,To和OQV,每天1天和每天20分钟,在≥8小时的磨损后第7天。 OQV测量包括客观散射指数(OSI)的变化,稳定性指数(SI)和在20秒的一段时间内计算的波动指数(FI)。结果:TMH在20分钟的所有镜片的磨损中保持不变,但在Delefilcon A和Stenfilcon A的8小时内(第7天)之后,显着降低了(在第7天)。镜头前Nibut与所有透镜显着减少,而用任何镜头观察到未显着变化。 SI和FI在两种磨损时间都有显着增加。结论:虽然眼睛的任何隐形眼镜的存在挑战撕裂薄膜,但与Delefilcon A和Stenfilcon相比,Nesofilcon a隐形眼镜尽管是含水量高,但与斯蒂尔康A和Stenfilcon a隐形眼镜相比,呈下效果较低。我们推测出佩戴Nesofilcon的镜片时透镜可以转化为改善主观舒适性,但这仍有待评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号