Vitreous Reflux Frequency and Intraocular Pressure After First-Time Intravitreal Aflibercept Injections: Comparison of 30- and 32-Gauge Needles

机译:首次玻璃体玻璃体术后玻璃体回流频率和眼内压力注射:30-仪表针比较

获取原文
           

摘要

Purpose: To compare the effects of 30-gauge versus 32-gauge needles on vitreous reflux (VR) frequency and intraocular pressure (IOP) following first-time intravitreal aflibercept injections. Materials and Methods: Overall, 116 patients (116 eyes) who received intravitreal injections using 30-gauge needles and 104 patients (104 eyes) who received the same injection using 32-gauge needles were reviewed. The medical records of 116 patients who each received an intravitreal injection using a 30-gauge needle (median age: 67.5 ± 13.9 years) and 104 patients who each received the same injection using a 32-gauge needle (median age: 66. 3 ± 10.6 years) from January 2015 to June 2019 were compared. Results: No significant difference in the frequency of VR was observed between patients injected using 30-gauge needles (38/116) and patients injected using 32-gauge needles (31/104, P = 0.64). There were no significant differences in the VR rates of patients with phakic and pseudophakic eyes between those injected using 30-gauge ( P = 0.94) or 32-gauge needles ( P = 0.77). Axial length did not significantly differ between patients with and without VR when injected using 30-gauge ( P = 0.89) and with 32-gauge needles ( P = 0.69). IOP immediately after injection was significantly higher in patients injected using 30-gauge needles than in patients injected using 32-gauge needles ( P 0.01). Conclusion: VR frequency was not correlated with needle size, lens status, or axial length. Patients receiving injections using 30-gauge needles had higher IOP immediately after intravitreal injection.
机译:目的:在首次玻璃体玻璃体术后,比较30尺度与32尺针的影响对玻璃体回流(VR)频率和眼内压(IOP)的影响。材料和方法:综述了116名患者(116只眼)使用30尺针和104名患者(104名眼睛)接受使用32尺针接受相同喷射的104名患者(104只眼睛)。 116名患者的医疗记录,每个患者使用30·仪表针(中位数:67.5±13.9岁)和104名患者使用32号针(中位数:66.3±36.3±36.比较2015年1月至2019年6月,比较了10.6岁。结果:使用30仪针刺(38/116)注射患者的VR频率没有显着差异(38/116),并使用32尺针注射患者(31/104,p = 0.64)。使用30尺度(p = 0.94)或32尺度针(p = 0.77)注入的患者患者的患者的VR患者VR患者VR率没有显着差异(P = 0.77)。在使用30尺度(P = 0.89)和32尺针(P = 0.69)时,轴长在没有VR的患者之间没有显着差异。注射后的IOP在使用30尺度针注射的患者中显着高于使用32尺度针注射的患者(P <0.01)。结论:VR频率与针尺寸,透镜状态或轴向长度无关。在玻璃体内注射后立即使用30尺针接受注射患者。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号