首页> 外文期刊>Clinical ophthalmology >Investigation into the quantitative and qualitative characteristics of choroidal melanoma through magnetic resonance imaging and B-scan ultrasound
【24h】

Investigation into the quantitative and qualitative characteristics of choroidal melanoma through magnetic resonance imaging and B-scan ultrasound

机译:通过磁共振成像和B扫描超声调查脉络膜瘤的定量和定性特征

获取原文
           

摘要

Objective: To investigate the homogeneity and vascularity of choroidal melanoma through magnetic resonance imaging (MRI) and brightness modulation (B-mode) ultrasound scan and their correlation with dimensions of tumor, as well as to measure the sensitivity of both modalities in retinal detachment (RD) detection. Materials and methods: This retrospective chart review included patients diagnosed with choroidal melanoma. All these patients underwent MRI scans using T2-weighted (T2-WI) and T1-weighted (T1-WI) sequences, before and after an intravenous injection of paramagnetic contrast material. The patients were also examined using a B-mode ultrasound scan, and the results from both modalities were compared (tumor homogeneity, tumor height, tumor base diameter, and tumor vascularity). Results: Forty-two patients (mean age =65.33±12.51 years) with choroidal melanoma were included in the study. Homogeneity was confirmed in 16 patients through ultrasound scan, in 19 patients through T1-WI sequence, in 21 patients through T2-WI sequence, and in 25 patients through T1-WI sequence + contrast (gadolinium). Patients with homogenous tumors presented with lower ( P =0.0045) mean height than that of those with nonhomogenous tumors, whereas no statistically significant difference was found for base diameter measurements ( P =0.056). Patients with tumors of high vascularity presented with greater mean height ( P =0.000638) and greater mean base diameter compared with those with tumors of low vascularity ( P =0.019543). RD was detected in 26 patients through T1-WI sequence, in 13 patients through T2-WI sequence, in 26 patients through T1-WI sequence + contrast, and in 32 patients through ultrasound scan, which proved to be the most sensitive modality. Conclusion: The height of choroidal melanoma was positively correlated with tumor’s homogeneity. Melanomas of greater height were found to be less homogenous, due to increased degeneration and higher occurrence of intratumoral hemorrhage. In addition, choroidal melanoma’s height was also positively correlated with the level of its vascularity. Finally, ultrasound scan was found to be more sensitive than MRI in the detection of RD.
机译:目的:探讨磁共振成像(MRI)和亮度调制(B型)超声扫描及其与肿瘤尺寸的相关性的脉络膜瘤的均匀性和血管性,以及测量视网膜脱离中的两种方式的敏感性( RD)检测。材料和方法:本回顾性图表综述包括诊断脉络膜瘤的患者。所有这些患者使用T2加权(T2-WI)和T1加权(T1-WI)序列,在静脉内注射顺磁性造影剂之前和之后进行MRI扫描。还使用B模式超声扫描检查患者,并比较两种方式的结果(肿瘤均匀性,肿瘤高度,肿瘤基础直径和肿瘤血管性)。结果:44例患者(平均年龄= 65.33±12.51岁),研究了脉络膜瘤。通过超声扫描,19例通过T1-Wi序列,21例通过T2-Wi序列,25例通过T1-Wi序列,通过T1-Wi序列,通过T1-Wi序列,通过T1-Wi序列+对比度(钆),在19例患者中确认了均匀性。患有均匀肿瘤的患者呈下较低的(p = 0.0045)平均高于非源性肿瘤的患者,而没有发现统计学上显着的差异用于基础直径测量(P = 0.056)。患有高血管肿瘤的患者,呈现较大平均高度(p = 0.000638)和更大的平均基础直径,与低血管间隙的肿瘤相比(p = 0.019543)。通过T1-Wi序列在26名患者中检测到Rd,通过T2-Wi序列,26例通过T1-Wi序列+对比度,通过超声扫描,在32名患者中,这被证明是最敏感的模态。结论:脉络膜瘤的高度与肿瘤的均匀性正相关。由于妥善变性和妥善出现血管内出血,发现更高高度的黑色素较少的均匀性。此外,脉络膜黑色素瘤的高度也与其血管性水平正相关。最后,发现超声扫描比在RD检测中比MRI更敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号