Collaborative Study to Validate Purity Determination by 1H Quantitative NMR Spectroscopy by Using Internal Calibration Methodology

机译:通过使用内部校准方法将1H定量NMR光谱验证纯度测定的协同研究

获取原文
           

摘要

NMR spectroscopy has recently been utilized to determine the absolute amounts of organic molecules with metrological traceability since signal intensity is directly proportional to the number of each nucleus in a molecule. The NMR methodology that uses hydrogen nucleus (1H) to quantify chemicals is called quantitative 1H-NMR (1H qNMR). The quantitative method using 1H qNMR for determining the purity or content of chemicals has been adopted into some compendial guidelines and official standards. However, there are still few reports in the literature regarding validation of 1H qNMR methodology. Here, we coordinated an international collaborative study to validate a 1H qNMR based on the use of an internal calibration methodology. Thirteen laboratories participated in this study, and the purities of three samples were individually measured using 1H qNMR method. The three samples were all certified via conventional primary methods of measurement, such as butyl p -hydroxybenzoate Japanese Pharmacopeia (JP) reference standard certified by mass balance; benzoic acid certified reference material (CRM) certified by coulometric titration; fludioxonil CRM certified by a combination of freezing point depression method and 1H qNMR. For each sample, 1H qNMR experiments were optimized before quantitative analysis. The results showed that the measured values of each sample were equivalent to the corresponding reference labeled value. Furthermore, assessment of these 1H qNMR data using the normalized error, En -value, concluded that statistically 1H qNMR has the competence to obtain the same quantification performance and accuracy as the conventional primary methods of measurement.
机译:最近利用NMR光谱法测定具有计量可追溯性的绝对量的有机分子,因为信号强度与分子中的每个细胞核的数量成比例。使用氢核(1H)量化化学物质的NMR方法称为定量1H-NMR(1H QNMR)。使用1H QNMR来确定化学品纯度或含量的定量方法已采用若干百强指引和官方标准。然而,关于验证1H QNMR方法论的文献中仍有很少的报道。在这里,我们协调了一个国际协同研究,根据使用内部校准方法来验证1H QNMR。第十三个实验室参与了这项研究,使用1H QNMR方法单独测量三个样品的纯度。所有三种样品都通过常规的初级测量方法认证,如丁基对p-羟基苯甲酸丁酯日本药典(JP)参考标准经质量平衡证明;苯甲酸认证参考资料(CRM)通过库仑滴定认证; FLUDIOXONIL CRM通过冷冻点凹陷方法和1H QNMR的组合认证。对于每个样品,在定量分析之前优化1H QNMR实验。结果表明,每个样品的测量值相当于相应的参考标记值。此外,使用归一化误差ZH -Value对这1H QNMR数据的评估得出结论,统计1H QNMR具有竞争力,以获得与传统的初级测量方法相同的量化性能和准确性。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号