首页> 外文期刊>BMC Veterinary Research >Ex vivo comparison of sliding knot ligatures vs. haemostatic clips for equine small intestinal mesenteric vessel occlusion
【24h】

Ex vivo comparison of sliding knot ligatures vs. haemostatic clips for equine small intestinal mesenteric vessel occlusion

机译:exvivo滑动结扎的比较与马上小肠肠系膜血管闭塞的血压夹

获取原文
           

摘要

In equine abdominal surgery, resection and anastomosis of strangulated intestine is a commonly performed procedure. To date, ligatures, vessel sealing devices and the ligate-divide stapler have been described for this use in horses. The objective of this study was to compare the application of haemostatic clips and ligatures to occlude equine mesenteric vessels. Portions of jejunum with ten associated mesenteric vessels were collected from 12 horses at a local abattoir and divided into two groups. Portions of intestine were divided into two sections comprising five vessels each and assigned to Group A or Group B. Each vessel was occluded with a triple ligature. In Group A, vessels were ligated with three circumferential ligatures tied with a sliding knot with two overthrows. In Group B, vessels were occluded with application of three haemoclips. The procedures were performed by the same experienced surgeon. Intestinal length, construction time and vessel leaking pressure were measured and compared between groups. The intestinal length (mean?±?SD) was 3.78?±?0.43?m in Group A and 3.04?±?0.83?m in Group B. The difference was not significant (p?=?0.297). The construction time (mean?±?SD) was 7.03?±?0.34?min in Group A and 2.40?±?0.43?min in Group B. The difference was significant (p??0.0001). The leaking pressure was 1000 (750–1050) mmHg (median, IQ range) in Group A and 1050 (800–1050) mmHg (median, IQ range) in Group B. The difference was not significant (p?=?0.225). Haemoclip application is comparable in terms of leaking pressure but quicker than sliding knots to apply.
机译:在马上手术中,杀死肠道的切除和吻合术是常见的程序。迄今为止,已经针对马匹中描述了迄今为止,血管密封装置和Liate划分订书机。本研究的目的是将止血夹和韧带的应用进行比较,以抵御马肠系膜血管血管。在局部Abattor的12匹马中收集了与十匹相关肠系膜内的Jejunum部分,并分为两组。分为两个肠中的部分,每个部分包括五个血管,并分配给A组或B组。每种容器被三重结扎堵塞。在A组中,用带有滑动结的三个圆周连接物连接,与两个推翻的滑动结扎。在B组中,血管堵塞,含有三个血管脂肪。该程序由同一经验的外科医生进行。测量肠长,施工时间和血管泄漏压力并在组之间进行比较。肠长(平均值?±sd)为3.78°?±0.43μm,b组中的3.04?±0.83Ω·m。差异不显着(p?= 0.297)。施工时间(平均值?±sd)为7.03?±0.34Ω·0.34Ω,B组中的2.40?±0.43?分钟。差异很大(P?<β0.0001)。 B组A和1050(800-1050)MMHG(中位数,IQ系列)MMHG(中位数,IQ系列)的泄漏压力为B组中的MMHG(中位数,IQ系列)。差异不显着(P?= 0.225) 。 Haemoclip应用在泄漏压力方面是可比的,但比滑动结更快地涂抹。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号