The actual operation of the power distribution systems asks for high standards concerning the performance of the system in terms of continuity and safety in supplying consumers on the one hand and the quality of the delivered energy on the other hand. Thus, the paper aims to present a complete analysis of the impact that the modification of the neutral treatment system in a 110 kV / MV station belonging to Energy Distribution Oltenia (DEO), has on both the number and the type of unwanted events or phenomena as well as on the network parameters and the transient regime which occurs as a result of some defects with the earth. All of these have been analyzed taking into account the new performance standards that distribution systems have to respect.
机译:配电系统的实际操作要求在一方面供应消费者的连续性和安全性方面有关系统性能的高标准,另一方面,交付能量的质量。因此,本文旨在完全分析,对属于能量分布Oltenia(DEO)的110 kV / MV站的中性处理系统改性的影响,对不需要的事件或现象的数量和类型以及在网络参数和由于地球缺陷而发生的瞬态制度。考虑到分配系统必须尊重的新绩效标准,所有这些都已分析。