首页> 外文期刊>Journal of Clinical Microbiology >High-Stringency Evaluation of the Automated BD Phoenix CPO Detect and Rapidec Carba NP Tests for Detection and Classification of Carbapenemases
【24h】

High-Stringency Evaluation of the Automated BD Phoenix CPO Detect and Rapidec Carba NP Tests for Detection and Classification of Carbapenemases

机译:自动化BD Phoenix CPO检测和Rapidec Carba NP测试对碳青霉烯酶的检测和分类的高严格性评估

获取原文

摘要

There is an urgent need for rapid, accurate detection and classification of carbapenemases. The current study evaluated the automated BD Phoenix CPO Detect and the manual bioMérieux Rapidec Carba NP tests for meeting these needs. Both tests were challenged with 294 isolates of Enterobacteriaceae spp., Pseudomonas aeruginosa, and Acinetobacter baumannii chosen to provide extreme diagnostic difficulty. Carbapenemases such as KPC, NMC-A, IMI, SME, NDM, SPM, IMP, VIM, and OXA-23, 40, 48, 58, 72, 181, and 232 were produced by 243 isolates and 51 carbapenemase-negative isolates included porin mutants and producers of extended-spectrum β-lactamases (ESBLs), AmpCs, K1, and broad-spectrum β-lactamases. Both tests exhibited high sensitivity of carbapenemase detection (97%). Due to the highly challenging carbapenemase-negative isolates, specificities were lower than typical for evaluations involving mostly routine clinical isolates. BD Phoenix CPO Detect was 68.6% specific and Rapidec Carba NP was 60.8% to 78.4% specific, depending on how borderline results were interpreted. Only BD Phoenix CPO Detect classified carbapenemases. It correctly classified 85.0% of class A, 72.4% of class B, and 88.6% of class D carbapenemases. Importantly with respect to empirical therapy with new β-lactamase inhibitor combinations such as ceftazidime/avibactam, no class B carbapenemases were misclassified as class A carbapenemases. Both tests offer advantages. Used alone, without initial susceptibility tests, Rapidec Carba NP can provide positive results for some isolates after only 10 to 30 min incubation. BD Phoenix CPO Detect provides novel advantages such as automated carbapenemase detection, inclusion in susceptibility panels to eliminate delays and subjectivity in initiating carbapenemase tests, and classification of most carbapenemases.
机译:迫切需要对碳青霉烯酶进行快速,准确的检测和分类。当前的研究评估了自动BD Phoenix CPO Detect和手动bioMérieuxRapidec Carba NP测试是否满足这些需求。两项测试均受到294株肠杆菌科细菌,铜绿假单胞菌和鲍曼不动杆菌的挑战,以提供极高的诊断难度。碳青霉菌酶(例如KPC,NMC-A,IMI,SME,NDM,SPM,IMP,VIM和OXA-23)分别由243株和51株碳青霉烯酶阴性菌株产生40、48、58、58、72、181和232孔蛋白突变体和广谱β-内酰胺酶(ESBLs),AmpCs,K1和广谱β-内酰胺酶的生产者。两种测试均显示出碳青霉烯酶检测的高灵敏度(> 97%)。由于具有高度挑战性的碳青霉烯酶阴性分离株,特异性低于典型的常规临床分离株评估的特异性。 BD Phoenix CPO Detect的特异性为68.6%,Rapidec Carba NP的特异性为60.8%至78.4%,这取决于对临界结果的解释方式。只有BD Phoenix CPO可以检测到分类的碳青霉烯酶。它正确分类了A类85.0%,B类72.4%和D类碳青霉烯酶88.6%。重要的是,关于使用新的β-内酰胺酶抑制剂组合(例如头孢他啶/阿维巴坦)进行的经验疗法,没有将B类碳青霉烯酶误分类为A类碳青霉烯酶。两种测试均具有优势。仅经过10到30分钟的孵育,Rapidec Carba NP即可单独使用,无需初步的药敏试验,就可以为某些分离株提供阳性结果。 BD Phoenix CPO Detect提供了新颖的优势,例如自动碳青霉烯酶检测,易感性面板中的产品,以消除启动碳青霉菌酶测试时的延迟和主观性,以及大多数碳青霉烯酶的分类。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号