The reliability of the MB/BACT system for susceptibility testing of Mycobacterium tuberculosis to pyrazinamide, rifampin, isoniazid, streptomycin, and ethambutol was compared to the BACTEC 460TB system. The proportion method was used to resolve discrepant results by an independent arbiter. Two interpretative methods were used, with an undiluted control (direct control) and a diluted control (10?1 control). As no significant difference was observed between the two controls, the method with the direct control was adopted as the most accurate one. One hundred sixty-six strains were tested, with an overall agreement of 98.3%. After resolution of the 18 discrepant results by the proportion method, the sensitivity and specificity of the MB/BACT system were 100% for rifampin, isoniazid, and pyrazinamide. For ethambutol, sensitivity was 92.3% at the critical concentration and 33% at the high concentration, and specificity was 100% at both concentrations. For streptomycin, sensitivity was 100% at the critical concentration and 80% at the high concentration, and specificity was 98.6% at the critical concentration and 100% at the high concentration. The rifampin, isoniazid, streptomycin, and ethambutol susceptibility test results were obtained in 6.6 days with the MB/BACT versus 5 days with the BACTEC 460TB. The pyrazinamide susceptibility test results were obtained in 7.8 days with the MB/BACT, versus 6.7 days with the BACTEC 460TB. These data demonstrate that the fully automated MB/BACT system is a very reliable method for rapid susceptibility testing of M. tuberculosis against rifampin, isoniazid, and pyrazinamide. Sensitivity results have to be improved for ethambutol and streptomycin, especially at the high concentration.
机译:将MB / BACT系统对结核分枝杆菌对吡嗪酰胺,利福平,异烟肼,链霉素和乙胺丁醇的药敏试验的可靠性与BACTEC 460TB系统进行了比较。比例法用于由独立仲裁员解决不一致的结果。使用两种解释方法,未稀释的对照(直接对照)和稀释的对照(10 ?1 对照)。由于在两个对照之间未观察到显着差异,因此采用具有直接对照的方法作为最准确的方法。测试了166个菌株,总符合率为98.3%。通过比例法解析出18个差异结果后,MB / BACT系统对利福平,异烟肼和吡嗪酰胺的敏感性和特异性为100%。对于乙胺丁醇,临界浓度下的敏感性为92.3%,高浓度下的敏感性为33%,两种浓度的特异性均为100%。对于链霉素,敏感性在临界浓度下为100%,在高浓度下为80%,在临界浓度下的特异性为98.6%,在高浓度下的特异性为100%。使用MB / BACT的6.6天,使用BACTEC 460TB的5天获得了利福平,异烟肼,链霉素和乙胺丁醇的药敏试验结果。使用MB / BACT在7.8天获得吡嗪酰胺敏感性测试结果,而使用BACTEC 460TB则需要6.7天获得吡嗪酰胺敏感性测试结果。这些数据表明,全自动MB / BACT系统是用于 M快速敏感性测试的非常可靠的方法。结核对利福平,异烟肼和吡嗪酰胺的影响。乙胺丁醇和链霉素的敏感性结果必须改善,尤其是在高浓度下。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号