首页> 外文期刊>Journal of Clinical Microbiology >Rapid detection of bacterial growth in blood samples by a continuous-monitoring electrical impedance apparatus.
【24h】

Rapid detection of bacterial growth in blood samples by a continuous-monitoring electrical impedance apparatus.

机译:通过连续监测电阻抗装置快速检测血液样本中的细菌生长。

获取原文
           

摘要

A growth detection method utilizing an automated apparatus capable of rapidly detecting bacterial growth by measuring changes of electrical impedance in bacteriological medium was utilized with "mock" blood cultures containing various gram-negative and gram-positive bacteria. Measurement of changes of electrical impedance was found to ba as accurate and comparable for time of growth detection as the radiometric method for detection of the same bacteria using mock blood cultures. In a limited clinical trial the use of the electrical impedance apparatus detected in 1 positive specimen from 40 clinical blood specimens as rapidly as by radiometric measurement. Both methods were considerably faster for detecting bacterial growth as compared with conventional culture methods. The selected species of gram-positive and -negative organisms tested were all detected by the electrical impedance method, including aerobes and anerobes. However, addition of 5% CO2 to the incubation atmosphere enhanced detection of gram-positive organisms.
机译:利用利用能够通过测量细菌培养基中的电阻抗变化来快速检测细菌生长的自动化设备的生长检测方法,与含有各种革兰氏阴性和革兰氏阳性细菌的“模拟”血液培养物一起使用。发现电阻抗变化的测量对于生长时间的检测与使用模拟血液培养物检测相同细菌的放射线测量方法一样准确且可比。在一项有限的临床试验中,使用电阻抗仪的速度与放射测量法一样快,可从40个临床血液样本中检测出1个阳性样本。与常规培养方法相比,这两种方法在检测细菌生长方面都快得多。所选的革兰氏阳性和阴性菌种均通过电阻抗方法检测,包括需氧菌和需氧菌。但是,在培养气氛中添加5%的CO2可以提高革兰氏阳性生物的检测率。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号