Few high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods have been developed for the full quantitation of fatty acids from human plasma without derivatization. Therefore, we propose a method that requires fewer sample preparation steps, which can be used for the quantitation of several polyunsaturated fatty acids in human plasma. The method offers rapid, accurate, sensitive, and simultaneous quantification of omega 3 (α-linolenic, eicosapentaenoic, and docosahexaenoic acids) and omega 6 fatty acids (arachidonic and linoleic acids) using high-performance LC-MS/MS. The selected fatty acids were analysed in lipid extracts from both free and total forms. Chromatographic separation was achieved using a reversed phase C18 column with isocratic flow using ammonium acetate for improving negative electrospray ionization (ESI) response. Mass detection was performed in multiple reaction monitoring (MRM) mode, and deuterated internal standards were used for each target compound. The limits of quantification were situated in the low nanomolar range, excepting linoleic acid, for which the limit was in the high nanomolar range. The method was validated according to the U.S. Department of Health and Human Services guidelines, and offers a fast, sensitive, and reliable quantification of selected omega 3 and 6 fatty acids in human plasma.
机译:很少有高效液相色谱-串联质谱法(LC-MS / MS)用于从人血浆中完全定量而不衍生化脂肪酸的方法。因此,我们提出了一种需要较少样品制备步骤的方法,该方法可用于定量人血浆中的几种多不饱和脂肪酸。该方法可使用高性能LC-MS / MS快速,准确,灵敏地同时定量测定ω3(α-亚麻酸,二十碳五烯酸和二十二碳六烯酸)和ω6脂肪酸(花生四烯酸和亚油酸)。从自由和总形式的脂质提取物中分析了选定的脂肪酸。使用反相C18色谱柱和等度流动,使用乙酸铵进行色谱分离,以改善负电喷雾电离(ESI)反应。在多反应监测(MRM)模式下进行质量检测,并将氘代内标物用于每种目标化合物。定量极限位于低纳摩尔范围内,亚油酸除外,亚油酸的极限位于高纳摩尔范围内。该方法已根据美国卫生与公共服务部的指南进行了验证,可对人血浆中所选的ω3和6脂肪酸进行快速,灵敏和可靠的定量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号