首页> 外文期刊>EPJ Web of Conferences >Compression, Tension and Shear Testing of Fibrous Composite with the Split Hopkinson Bar Technique
【24h】

Compression, Tension and Shear Testing of Fibrous Composite with the Split Hopkinson Bar Technique

机译:分裂霍普金森棒技术对纤维复合材料的压缩,拉伸和剪切测试

获取原文

摘要

The Split Hopkinson Bar (SHB) technique is used for high strain rate testing of T800/F3900 composite in compression, tension and shear. Digital Image Correlation (DIC) is used for measuring the full-field deformation on the surface of the specimen by using Shimadzu HPV-X2 high-speed video camera. Compression tests have been done on specimens machined from a unidirectional laminate in the 0°and 90° directions. Tensile tests were done in the 90° direction. Shear tests were done by using a notched specimen in a compression SHB apparatus. To study the effect of strain rate, quasi-static testing was also done using DIC and specimens with the same geometry as in the SHB tests. The results show that the DIC technique provides accurate strain measurements even at strains that are smaller than 1%. No strain rate effect is observed in compression in the 0° direction and significant strain rate effects are observed in compression and tension in the 90° direction, and in shear.
机译:Split Hopkinson Bar(SHB)技术用于压缩,拉伸和剪切下的T800 / F3900复合材料的高应变率测试。数字图像相关(DIC)用于通过使用Shimadzu HPV-X2高速摄像机测量样品表面的全视场变形。已经对由单向层压板在0°和90°方向上加工的样品进行了压缩测试。沿90°方向进行拉伸测试。剪切试验是通过在压缩SHB装置中使用带缺口的样品进行的。为了研究应变率的影响,还使用DIC和具有与SHB测试相同几何形状的样本进行了准静态测试。结果表明,即使在小于1%的应变下,DIC技术仍可提供准确的应变测量。在0°方向的压缩中未观察到应变率效应,而在90°方向的压缩和拉伸中以及剪切时均未观察到明显的应变率效应。