首页> 外文期刊>Investigative ophthalmology & visual science >Comparison of Several Parameters in Two Optical Coherence Tomography Systems for Detecting Glaucomatous Defects in High Myopia
【24h】

Comparison of Several Parameters in Two Optical Coherence Tomography Systems for Detecting Glaucomatous Defects in High Myopia

机译:两种用于高度近视眼的青光眼缺陷的光学相干断层扫描系统中几个参数的比较

获取原文
           

摘要

Purpose: To compare the diagnostic powers of parameters of the RTVue and Cirrus-HD optical coherence tomography (OCT) systems in detecting glaucoma in highly myopic eyes. Methods: For this study, 28 glaucoma patients with high myopia (HM-G) and 28 high-myopia controls (HM-C) were enrolled. The circumpapillary retinal nerve fiber layer (cp-RNFL) and ganglion cell complex (GCC) parameters in the RTVue-OCT, and the ganglion cella??inner plexiform layer (GCIPL) and cp-RNFL parameters in the Cirrus HD-OCT, were obtained for each subject. The receiver operating characteristics curve (ROC) was used to assess the diagnostic ability of each parameter, and the areas under the curves (AUROCs) of those parameters were compared. Results: In both OCTs, the macular parameters showed significantly higher diagnostic power than the cp-RNFL thickness. The minimum GCIPL (0.977), inferotemporal GCIPL (0.947), and vertical cup/disc (C/D) ratio (0.968) showed the best performances among all of the Cirrus HD-OCT parameters. The focal loss volume (FLV) (0.964), global loss volume (GLV) (0.899), and vertical C/D ratio (0.899) showed the best performances among all of the RTVue-OCT parameters. Among the parameters with high diagnostic ability in each protocol of the two OCTs, the superior sector of the cp-RNFL had significantly lower abilities than the FLV and the minimum of the GCIPL (P 0.05) in detecting glaucoma in high myopia. Conclusions: The macular measurements had significantly better glaucoma detection abilities than the cpRNFL thickness in the high-myopia subjects in both RTVue-OCT and Cirrus HD-OCT, with no significant differences in the diagnostic ability between the two macular parameters.
机译:目的:比较RTVue和Cirrus-HD光学相干断层扫描(OCT)系统的参数在检测高度近视眼中的青光眼中的诊断能力。方法:本研究招募了28例高度近视的青光眼患者(HM-G)和28例高度近视的对照组(HM-C)。 RTVue-OCT中的视神经乳头视网膜神经纤维层(cp-RNFL)和神经节细胞复合体(GCC)参数,以及Cirrus HD-OCT中的神经节细胞-内神经丛层(GCIPL)和cp-RNFL参数为获得每个主题。使用接收器工作特性曲线(ROC)评估每个参数的诊断能力,并比较这些参数的曲线下面积(AUROC)。结果:在两个OCT中,黄斑参数均显示出比cp-RNFL厚度显着更高的诊断能力。在所有Cirrus HD-OCT参数中,最小GCIPL(0.977),颞下GCIPL(0.947)和垂直杯/碟(C / D)比(0.968)表现出最佳性能。焦点损失量(FLV)(0.964),全局损失量(GLV)(0.899)和垂直C / D比(0.899)在所有RTVue-OCT参数中显示出最佳性能。在两个OCT的每个协议中,具有高诊断能力的参数中,cp-RNFL的上级扇区在高度近视眼中检测青光眼的能力显着低于FLV,而GCIPL的能力最低(P <0.05)。结论:在RTVue-OCT和Cirrus HD-OCT中,在高度近视受试者中,黄斑测量具有比cpRNFL厚度更好的青光眼检测能力,而在两个黄斑参数之间的诊断能力没有显着差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号