首页> 外文期刊>IFAC PapersOnLine >Optimal Steady-State Temperature Field in an Experimental Annealing Furnace
【24h】

Optimal Steady-State Temperature Field in an Experimental Annealing Furnace

机译:实验退火炉中的最佳稳态温度场

获取原文

摘要

Abstract: The computation of an optimal steady-state operating point in an experimental annealing furnace is considered. In particular, the optimum spatial distribution of electric power supplied to IR-lamps is computed to ensure the temperature uniformity in the specimen fillet. A control-oriented reduced-order model of the steady-state 2D temperature distribution is derived and compared with the full-order model. Saturation functions are used to consider input constraints in a tailored optimization problem. The evaluation of the optimal control input is carried out with the full-order model. Uniqueness of the solution of the optimization problem is investigated numerically. The temperature field in the specimen fillet deviates less than 0.4% of the setpoint value if sufficient heating power is available.
机译:摘要:考虑了在实验退火炉中最佳稳态工作点的计算。特别是,计算提供给IR灯的最佳功率空间分布,以确保样品圆角的温度均匀性。导出了稳态二维温度分布的面向控制的降阶模型,并将其与全阶模型进行比较。饱和函数用于考虑定制优化问题中的输入约束。最佳控制输入的评估是通过全阶模型进行的。数值研究了优化问题解的唯一性。如果有足够的加热功率,则样品圆角中的温度场偏离设定值的0.4%以下。