Model system using coliphage phi X174 for testing virus removal by air filters.

机译:使用大肠杆菌噬菌体phi X174的模型系统,用于测试通过空气过滤器去除病毒的能力。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Short-term (15-min-duration) and long-term (5- to 6-day-duration) test procedures have been developed for determining the efficiency of the removal of bacteriophage phi X174 by air-sterilizing filters. These procedures were sensitive enough to measure a 10(8)-fold reduction in the number of bacteriophage. A filter commonly used in industrial air sterilizations (Domnick-Hunter Bio-X borosilicate glass) effected a 10(8)-fold removal of viable phage in both short-term and long-term tests. A prototype low-flux, hollow-fiber membrane gave similar results; however, a prototype high-flux, hollow-fiber membrane removed only about 99.999% of the bacteriophage in short-term tests.
机译:已经开发了短期(15分钟持续时间)和长期(5至6天持续时间)测试程序,用于确定通过空气消毒过滤器去除phiX174噬菌体的效率。这些程序足够灵敏,可以测量到噬菌体数量减少10(8)倍。在短期和长期测试中,工业空气消毒中常用的过滤器(Domnick-Hunter Bio-X硼硅酸盐玻璃)可去除活噬菌体的10(8)倍。低通量,中空纤维膜的原型得到了相似的结果。然而,在短期测试中,原型高通量中空纤维膜仅除去了约99.999%的噬菌体。