...
首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >ELISA for thyroglobulin in serum: recovery studies to evaluate autoantibody interference and reliability of thyroglobulin values.
【24h】

ELISA for thyroglobulin in serum: recovery studies to evaluate autoantibody interference and reliability of thyroglobulin values.

机译:血清中甲状腺球蛋白的ELISA:回收研究以评估自身抗体的干扰和甲状腺球蛋白值的可靠性。

获取原文
           

摘要

An ELISA for measuring thyroglobulin (Tg) in serum was developed with polyclonal antibodies to Tg on the solid phase and two monoclonal antibodies to Tg as the second antibodies. The assay has a detection limit of 1 microgram/L, a within-run imprecision (CV) of 7%, and a between-run CV of 10%. Parallelism of the assay was shown in dilution studies, in which the percent observed/expected values for n = 5 autoantibody-containing samples gave a mean of 99% (SD 13.1 %); for n = 5 samples with undetectable autoantibody concentrations, the mean was 103% (SD 11.8%). The correlation of the ELISA with an RIA for Tg in 46 normal samples was ELISA = 1.11(RIA) + 0.52, S y/x = 2.23, SD intercept = 0.54, SD slope = 0.03, range = 0 to 53 micrograms/L, r = 0.980. Comparison of the ELISA with a reference laboratory RIA for 29 clinical samples gave a correlation of: ELISA = 1.53(RIA) - 0.48, S y/x = 9.00, SD intercept = 2.19, SD slope = 0.10, range = 0 to 98 micrograms/L, r = 0.950. To provide additional information concerning the reliability of the Tg measurement in samples containing autoantibodies to Tg, we developed a procedure for determining the percent recovery. A percent recovery greater than or equal to 80% indicates minimal interference by autoantibodies in this assay. The assay is straightforward to perform, results can be posted within 8 h, and the routinely good recovery of Tg in the presence of Tg autoantibodies indicates minimal autoantibody interference in this assay.
机译:用固相抗Tg的多克隆抗体和两种抗Tg的单克隆抗体作为第二抗体开发了一种用于测定血清中甲状腺球蛋白(Tg)的ELISA。该测定法的检测极限为1微克/升,批内不精密度(CV)<7%,批间CV <10%。稀释研究显示了测定的平行性,其中n = 5的含自身抗体样品的观察/预期值的百分数平均为99%(SD 13.1%);对于n = 5个无法检测到的自身抗体浓度的样品,平均值为103%(标准差为11.8%)。 ELISA与46个正常样品中Tg的RIA的相关性为ELISA = 1.11(RIA)+ 0.52,S y / x = 2.23,SD截距= 0.54,SD斜率= 0.03,范围= 0至53微克/ L, r = 0.980。 ELISA与参考实验室RIA对29种临床样品的比较得出以下相关性:ELISA = 1.53(RIA)-0.48,S y / x = 9.00,SD截距= 2.19,SD斜率= 0.10,范围= 0至98微克/L,r=0.950。为了提供有关含有Tg自身抗体的样品中Tg测量可靠性的其他信息,我们开发了一种确定回收率百分比的程序。回收率大于或等于80%表示在此测定法中自身抗体的干扰最小。该测定法易于执行,结果可在8小时内发布,并且在存在Tg自身抗体的情况下,Tg常规恢复良好,表明该测定法对自身抗体的干扰最小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号