We optimized storage conditions and validated a sensitive immunofluorometric assay (IFMA) for urinary gonadotropins. Assay linearity and parallelism for luteinizing hormone (LH) and follicle-stimulating hormone (FSH) was observed to 0.04 IU/L. Urinary LH and FSH were unaffected by changes of osmolarity from 0.5 to 3.0 mOsm/kg, and from pH 4.5 to 10.5. Serum and urine measurements of the hormones correlated well over a wide range of values: for LH, R2 = 0.94, P 0.01; for FSH, R2 = 0.71, P 0.01 (n = 304). Preservation of urine with glycerol (70 mL/L) and storage at -20 degrees C yielded 80% recovery of LH and FSH after 51 weeks; this was comparable with recovery for acetone extracts of urine. Untreated urine showed loss of activity by 4 weeks of storage. Preserving urine specimens with glycerol is a simple method of storage for longitudinal study and compares favorably with acetone extraction. IFMAs can measure urinary gonadotropins reproducibly over a wide range of pH and osmotic conditions.
机译:我们优化了储存条件,并验证了尿促性腺激素的灵敏免疫荧光测定(IFMA)。促黄体生成激素(LH)和促卵泡激素(FSH)的测定线性和平行度为0.04 IU / L。渗透压从0.5到3.0 mOsm / kg,从pH 4.5到10.5,尿LH和FSH不受影响。激素的血清和尿液测量值在很宽的范围内有很好的相关性:对于LH,R2 = 0.94,P <0.01;对于LH,R2 = 0.94,P <0.01。对于FSH,R2 = 0.71,P <0.01(n = 304)。用甘油(70 mL / L)保存尿液并在-20摄氏度下保存51周后LH和FSH回收率> 80%;这与尿液丙酮提取物的回收率相当。未经处理的尿液在储存4周后显示出活性降低。用甘油保存尿液标本是一种用于纵向研究的简单存储方法,与丙酮提取相比具有优势。 IFMA可以在很宽的pH值和渗透条件下可重复测量尿促性腺激素。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号