首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Three commercial kits and one liquid-chromatographic method evaluated for determining 25-hydroxyvitamin D3 in serum.
【24h】

Three commercial kits and one liquid-chromatographic method evaluated for determining 25-hydroxyvitamin D3 in serum.

机译:评估了三种商用试剂盒和一种液相色谱方法,用于测定血清中的25-羟基维生素D3。

获取原文
           

摘要

The accuracy of three commercial kit methods and one liquid-chromatographic (HPLC) method for determining 25-hydroxyvitamin D3 in serum was evaluated by using isotope dilution-mass spectrometry as a reference technique. The kit methods were based on radioimmunoassay and radioreceptor assay. Serum samples were analyzed from male and female volunteers, some of whom had been exposed to ultraviolet B light or given vitamin D3 orally. Results obtained with the three commercial kits were less accurate than those by HPLC. The agreement between the HPLC method and the comparison method was relatively good: r = 0.99; slope = 1.23; intercept = -2.9 micrograms/L. We conclude that methods based on HPLC should be preferred in routine clinical work and that the accuracy of the three commercial kits tested is not sufficient for their intended use.
机译:通过使用同位素稀释质谱法作为参考技术,评估了三种市售试剂盒方法和一种液相色谱(HPLC)方法测定血清中25-羟基维生素D3的准确性。试剂盒方法基于放射免疫测定和放射受体测定。对男性和女性志愿者的血清样本进行了分析,其中一些志愿者暴露于紫外线B照射或口服维生素D3。使用三种市售试剂盒获得的结果不如通过HPLC获得的结果准确。 HPLC方法与比较方法之间的一致性相对较好:r = 0.99;斜率= 1.23;截距= -2.9微克/升。我们得出结论,在常规临床工作中应首选基于HPLC的方法,并且所测试的三种商业试剂盒的准确性不足以用于其预期用途。