首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Simple liquid-chromatographic determination of urinary coproporphyrin in workers exposed to lead.
【24h】

Simple liquid-chromatographic determination of urinary coproporphyrin in workers exposed to lead.

机译:简单的液相色谱法测定铅作业工人中的尿卟啉。

获取原文

摘要

We developed a simple method for the determination of urinary coproporphyrin (CP) in lead workers, using a "high-performance" liquid chromatograph (HPLC) equipped with a fluorescence detector. The detection limit of urinary CP in this method was 5 micrograms per liter of urine. The working linear range of urinary CP concentration was 5 to 1500 micrograms/L. In 41 lead-exposed workers, the urinary CP values obtained by the present HPLC method were well correlated with those obtained by a conventional spectrophotometric method (r = 0.94). The present method is useful for screening workers exposed to lead.
机译:我们使用配备有荧光检测器的“高效”液相色谱仪(HPLC),开发了一种简单的方法来测定铅工作人员中的尿卟啉(CP)。该方法中尿CP的检测极限为每升尿5微克。尿CP浓度的工作线性范围是5-1500微克/升。在41名铅接触工人中,通过本HPLC方法获得的尿CP值与通过常规分光光度法获得的尿CP值高度相关(r = 0.94)。本方法对于筛选暴露于铅的工人是有用的。

著录项