首页> 外文期刊>Clinical Chemistry: Journal of the American Association for Clinical Chemists >Comparison of Radioimmunoassay with Thin-Layer Chromatographic and Gas—Liquid Chromatographic Methods of Barbiturate Detection in Human Urine
【24h】

Comparison of Radioimmunoassay with Thin-Layer Chromatographic and Gas—Liquid Chromatographic Methods of Barbiturate Detection in Human Urine

机译:尿液中巴比妥酸盐检测的薄层色谱法和气相色谱法进行放射免疫分析的比较

获取原文

摘要

A radioimmunoassay (I) for barbiturates was compared with thin-layer chromatographic (II) and gas—liquid chromatographic (III) methods for barbiturate detection in human urine. Timed urine samples were obtained from volunteers who had ingested 100 mg of a barbiturate. I detected barbiturate in all urines tested up to 76 h after the dose, and III in all up to 52 h and in 90% up to 76 h. II detected barbiturates in 90% of all urine samples for only 30 h, after which its reliability declined. Glutethimide interfered with radioimmunoassay of barbiturate, producing false positives. I is sensitive, reliable, and fast, and lends itself to screening large numbers of urine samples for barbiturates. For routine urine surveillance, however, we found I to be less useful than II, which is still the method of choice. I has, however, proved to be an excellent method for confirming resuits of II.
机译:将巴比妥酸盐的放射免疫分析(I)与薄层色谱法(II)和气相色谱法(III)检测人尿中的巴比妥酸盐的方法进行了比较。定时尿液样本是从摄入了100毫克巴比妥酸盐的志愿者那里获得的。在剂量给药后长达76 h的所有尿液中,我均检测到巴比妥酸盐,在长达52 h的所有尿液中均检测到巴比妥酸盐,直至76 h的90%均检测到III。 II仅在30小时内就在所有尿液样本中检测了90%的巴比妥酸盐,此后其可靠性下降。谷氨乙酰亚胺干扰了巴比妥酸盐的放射免疫测定,产生假阳性。我敏感,可靠,快速,适合筛查大量尿液中的巴比妥类药物。但是,对于常规的尿液监测,我们发现I的作用比II的作用小,II仍然是选择的方法。但是,事实证明,我是确认II重复的极好方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号