In this fully automated technique for sample cleanup before chromatographic or other quantitation steps, analytes in body fluids are enriched and semi-purified on a first column. After their selective elution, analytes are "transformed" by admixing appropriate solvents in such a way that they are focused on the top of a second column. By backflush, they then are transferred to an analytical liquid-chromatographic column (or simply eluted for quantification by other techniques). This technique is illustrated by the liquid-chromatographic assay of triamcinolone from a 1-mL urine sample, with ultraviolet detection. Because analytical recovery is almost complete and precision high, no internal standardization is necessary. Interference is eliminated as well as or better than with manual techniques. Chief advantages of this technique are online operation, processing of samples of larger volume, low cost with respect to extraction devices, and nearly universal applicability for exogenous or endogenous compounds of clinical relevance. It potentially may be widely applied.
机译:在色谱或其他定量步骤之前的这种用于样品净化的全自动技术中,体液中的分析物在第一根色谱柱上进行了富集和半纯化。选择性洗脱后,通过混合适当的溶剂使分析物“转化”,使它们聚焦在第二个色谱柱的顶部。通过反吹,然后将它们转移至分析型液相色谱柱(或简单地通过其他技术洗脱进行定量)。液相色谱法测定1-mL尿液中曲安西龙并进行紫外线检测,可以说明这项技术。由于分析回收几乎完成且精度很高,因此不需要内部标准化。与手动技术相比,消除的干扰效果更好或更好。该技术的主要优点是在线操作,处理更大体积的样品,相对于提取设备而言成本低,以及对具有临床意义的外源性或内源性化合物的普遍适用性。它可能被广泛应用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号