首页> 外文期刊>BioMed research international >Evaluation of Corneal Biomechanical Properties Modification after Small Incision Lenticule Extraction Using Scheimpflug-Based Noncontact Tonometer
【24h】

Evaluation of Corneal Biomechanical Properties Modification after Small Incision Lenticule Extraction Using Scheimpflug-Based Noncontact Tonometer

机译:基于Scheimpflug的非接触眼压计评估小切口小孔摘除后角膜生物力学性能的评估

获取原文
           

摘要

Purpose.To quantify the effect of small incision lenticule extraction (SMILE) on the corneal biomechanics using Scheimpflug noncontact tonometer (Corvis ST).Methods.Twenty eyes of twenty patients, evaluated as eligible for surgery, with high myopia and/or moderate myopic astigmatism, underwent small incision lenticule extraction (SMILE). All patients underwent Corvis ST preoperatively and postoperatively after 1 week, and 1 and 3 months to observe alterations of corneal biomechanical properties. The main outcome measures were Deformation Amplitude, 1st-AT, and 2nd-AT. The relationship between the amount of stroma removed and the percentage variation of the measured parameters from baseline was evaluated with generalized linear model from each time point. For completeness also intraocular pressure (IOP), central corneal thickness (CCT), and their variations after surgery were evaluated.Results.The ratio between the amount of removed refractive error and, respectively, changes of Deformation Amplitude, 1st-AT, and 2nd-AT were significantly modified at the 1st week after surgery(P=0.005; P=0.001; P=0.024). At 1 and 3 months these values did not show statistically significant alterations. Intraocular pressure and central corneal thickness showed statistically significant changes during follow-up.Conclusions.No significant modifications in biomechanical properties were observed after SMILE so this procedure could induce only minimal transient alterations of corneal biomechanics.
机译:目的:使用Scheimpflug非接触式眼压计(Corvis ST)量化小切口小孔摘除术(SMILE)对角膜生物力学的影响。方法。二十名患者的20眼被评估为适合手术的高度近视和/或中度近视散光。 ,进行小切口小孔摘除术(SMILE)。所有患者均在术前和术后1周,1和3个月接受Corvis ST手术,以观察角膜生物力学特性的变化。主要结果指标为变形幅度,第一个AT和第二个AT。使用广义线性模型从每个时间点评估基质去除量与测量参数相对于基线的百分比变化之间的关系。为了完整起见,还评估了眼内压(IOP),中央角膜厚度(CCT)及其在手术后的变化。结果:屈光不正的去除量与变形幅度,第1次AT和第2次变化之间的比率-AT在手术后第一周发生了显着改变(P = 0.005; P = 0.001; P = 0.024)。在第1和3个月时,这些值没有显示出统计学上的显着变化。随访期间眼压和角膜中央厚度显示出统计学上的显着变化。结论:SMILE后未观察到生物力学性质的显着改变,因此该程序仅能引起角膜生物力学的最小瞬时变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号