首页> 外文期刊>Journal of Medical Physics/Association of Medical Physicists of India >Optimized point dose measurement for monitor unit verification in intensity modulated radiation therapy using 6 MV photons by three different methodologies with different detector-phantom combinations: A comparative study
【24h】

Optimized point dose measurement for monitor unit verification in intensity modulated radiation therapy using 6 MV photons by three different methodologies with different detector-phantom combinations: A comparative study

机译:通过6种MV光子通过三种不同的方法和不同的检测器-幻像组合进行强度调制放射治疗中监测单元验证的最佳点剂量测量:一项比较研究

获取原文

摘要

The study was aimed to compare accuracy of monitor unit verification in intensity modulated radiation therapy (IMRT) using 6 MV photons by three different methodologies with different detector phantom combinations. Sixty patients were randomly chosen. Zero degree couch and gantry angle plans were generated in a plastic universal IMRT verification phantom and 30×30×30 cc water phantom and measured using 0.125 cc and 0.6 cc chambers, respectively. Actual gantry and couch angle plans were also measured in water phantom using 0.6 cc chamber. A suitable point of measurement was chosen from the beam profile for each field. When the zero-degree gantry, couch angle plans and actual gantry, couch angle plans were measured by 0.6 cc chamber in water phantom, the percentage mean difference (MD) was 1.35%, 2.94 % and Standard Deviation (SD) was 2.99%, 5.22%, respectively. The plastic phantom measurements with 0.125 cc chamber Semiflex ionisation chamber (SIC) showed an MD=4.21% and SD=2.73 %, but when corrected for chamber-medium response, they showed an improvement, with MD=3.38 % and SD=2.59 %. It was found that measurements with water phantom and 0.6cc chamber at gantry angle zero degree showed better conformity than other measurements of medium-detector combinations. Correction in plastic phantom measurement improved the result only marginally, and actual gantry angle measurement in a flat- water phantom showed higher deviation.Keywords: Dose verification, point dose measurement, quality assurance
机译:这项研究旨在通过三种不同的方法和不同的检测器幻像组合,比较使用6 MV光子的强度调制放射治疗(IMRT)中监测器单元验证的准确性。随机选择60名患者。在塑料通用IMRT验证体模和30×30×30 cc水体模中生成零度卧榻和龙门角度计划,并分别使用0.125 cc和0.6 cc腔室进行测量。还使用0.6 cc的水箱在水体模中测量了实际的龙门架和床角计划。从每个领域的光束轮廓中选择合适的测量点。当以水模体中的0.6 cc腔室测量零度龙门架,床架角度计划和实际龙门架,床架角度计划时,百分比平均差(MD)为1.35%,2.94%,标准偏差(SD)为2.99%,分别为5.22%。使用0.125 cc腔室Semiflex电离腔室(SIC)进行的塑料体模测量显示MD = 4.21%和SD = 2.73%,但校正腔室-介质响应后,它们显示出改善,MD = 3.38%和SD = 2.59% 。结果发现,用水模和0.6cc室在龙门角零度下进行的测量显示出比其他中型探测器组合测量更好的一致性。塑性体模测量中的校正仅略微改善了结果,而平水体模中的实际龙门架角度测量显示出较大的偏差。关键词:剂量验证,点剂量测量,质量保证

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号