The simultaneous determination of sulfamethoxazole (SMX) and trimethoprim (TMP) mixtures in bovine milk by spectrophotometric method is a difficult problem in analytical chemistry, due to spectral interferences. By means of multivariate calibration methods, such as partial least square (PLS) regression, it is possible to obtain a model adjusted to the concentration values of the mixtures used in the calibration range. Genetic algorithm (GA) is a suitable method for selecting wavelengths for PLS calibration of mixtures with almost identical spectra without loss of prediction capacity using the spectrophotometric method. In this study, the calibration model based on absorption spectra in the 200-400 nm range for 25 different mixtures of SMX and TMP Calibration matrices were formed form samples containing 0.25-20 and 0.3-21 μg mL-1 for SMX and TMP, at pH=10, respectively. The root mean squared error of deviation (RMSED) for SMX and TMP with PLS and genetic algorithm partial least square (GAPLS) were 0.242, 0.066 μgmL-1 and 0.074, 0.027 μg mL-1, respectively. This procedure was allowed the simultaneous determination of SMX and TMP in synthetic and real samples and good reliability of the determination was proved.
机译:分光光度法同时测定牛乳中的磺胺甲恶唑(SMX)和甲氧苄啶(TMP)混合物,由于光谱干扰,在分析化学中是一个难题。借助多元校正方法,例如偏最小二乘(PLS)回归,可以获得一个模型,该模型调整为在校正范围内使用的混合物的浓度值。遗传算法(GA)是使用分光光度法选择波长进行几乎所有相同光谱的混合物的PLS校准的合适方法,而不会损失预测能力。在这项研究中,基于200-400 nm范围内吸收光谱的25种不同SMX和TMP混合物的校准模型是通过在0.25-20和0.3-21μgmL-1的SMX和TMP样品中形成的。 pH分别为10。具有SLS和TMP的PLS和遗传算法偏最小二乘(GAPLS)的均方根偏差均方根误差(RMSED)分别为0.242、0.066μgmL-1和0.074、0.027μgmL-1。该方法可以同时测定合成样品和实际样品中的SMX和TMP,并证明了测定的良好可靠性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号