首页> 外文期刊>Journal of nutrition and metabolism >Evaluation of Body Composition in Hemodialysis Thai Patients: Comparison between Two Models of Bioelectrical Impedance Analyzer and Dual-Energy X-Ray Absorptiometry
【24h】

Evaluation of Body Composition in Hemodialysis Thai Patients: Comparison between Two Models of Bioelectrical Impedance Analyzer and Dual-Energy X-Ray Absorptiometry

机译:泰国血液透析患者身体成分的评估:生物电阻抗分析仪和双能X射线吸收仪两种模型的比较

获取原文
       

摘要

Background. Body composition measurement is very important for early nutritional care in hemodialysis patients. Dual-energy X-ray absorptiometry (DXA) is a gold standard test, but clinically limited. Bioelectrical impedance analysis (BIA) with multifrequency technique is a practical and reliable tool. Objective. This cross-sectional study was aimed to compare the agreement of BIA with DXA in measurement of body composition in hemodialysis patients and to evaluate their associated factors. Methods. Body composition was measured by 2 BIA methods (InBody S10 and InBody 720) and DXA after a hemodialysis session. A total of 69 measurements were included. Pearson’s correlation and Bland and Altman analysis were used to determine the correlation of body composition between methods and to compare the methods agreement, respectively. Results. The correlation coefficients of body compositions were strong between DXA and InBody S10 (fat mass index (FMI) , fat-free mass index (FFMI) ) and also between DXA and InBody 720 (FMI , FFMI ). Comparing to DXA, the means of each body composition measured by InBody S10 method were not significantly different in each gender, but differences were found in FM, %FM, and FMI measured by InBody 720. Conclusions. In maintenance hemodialysis patients, the measurement of body composition with DXA and both BIA methods had highly significant correlations; practically, BIA method could be used as an instrument to follow FM and FFM and to measure the edematous stage. Further studies with large populations are warranted.
机译:背景。身体成分的测量对于血液透析患者的早期营养护理非常重要。双能X射线吸收法(DXA)是一项金标准测试,但临床上受到限制。采用多频技术的生物电阻抗分析(BIA)是一种实用且可靠的工具。目的。这项横断面研究旨在比较BIA与DXA在血液透析患者体内成分测量中的一致性,并评估其相关因素。方法。血液透析后,通过2种BIA方法(InBody S10和InBody 720)和DXA测量身体成分。总共包括69个测量值。皮尔逊相关性以及Bland和Altman分析分别用于确定方法之间的身体成分相关性,并比较方法的一致性。结果。在DXA和InBody S10之间(脂肪质量指数(FMI),无脂肪质量指数(FFMI)),以及在DXA和InBody 720之间(FMI和FFMI),人体成分的相关系数很强。与DXA相比,通过InBody S10方法测量的每种身体成分的平均值在各个性别上没有显着差异,但是在InBody 720测量的FM,%FM和FMI中发现差异。结论。在维持性血液透析患者中​​,用DXA和两种BIA方法测量身体成分具有高度显着的相关性。实际上,BIA方法可以用作追踪FM和FFM以及测量水肿阶段的工具。值得进一步研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号