Background:This study carried out was to assess the feasibility of using robotic microscopy (RM) for cytologic evaluation of direct smears from fine needle aspiration biopsy (FNAB). Methods:Three board-certified cytopathologists reviewed representative direct smears from 40 image-guided FNABs using RM and subsequently re-reviewed the same smears using conventional microscopy. Adequacy of the smears and cytologic diagnosis, as determined using the two approaches, were compared for each individual cytopathologist (intraobserver) and between the three cytopathologists (interobserver). The intraobserver and interobserver discrepancies were analyzed and discussed in a follow-up consensus conference. Results:For assessment of adequacy, there were high concordance rates (intraobserver: 92.5–97.5%; interobserver: 90–92.5%), with a few discrepancies involving distinctions between suboptimal and satisfactory smears. Analysis of diagnostic interpretations showed correct classification of 92.5–95% (intraobserver) or 90–92.5% (interobserver) of benign and malignant cases combined, with the discrepancies being between benign and atypical cells in the benign group, and between suspicious and malignant in the malignant group. Within the malignant group, 94% of cases were accurately subclassified via RM. The quality of images viewed by using RM was rated adequate (fair or good) for 95% of the slides. Conclusions:The results demonstrate that cytologic evaluation of direct smears from FNABs using RM is feasible. Problems encountered included the longer times needed to evaluate cases with thick, bloody smears and/or low numbers of diagnostic cells, and difficulties in recognizing neuroendocrine differentiation and mimics of hepatocellular carcinoma.
机译:背景:这项研究的目的是评估使用机器人显微镜(RM)对细针穿刺活检(FNAB)直接涂片进行细胞学评估的可行性。方法:三名经过董事会认证的细胞病理学家使用RM复查了40幅图像引导的FNAB的代表性直接涂片,随后使用常规显微镜复查了相同的涂片。比较了使用两种方法确定的涂片和细胞学诊断的适当性,分别针对了每位细胞病理学家(观察员)和三位细胞病理学家(观察员)。观察者内部和观察者之间的差异在后续共识会议中进行了分析和讨论。结果:为了评估是否足够,一致性率较高(观察者内:92.5–97.5%;观察者间:90–92.5%),其中一些差异涉及次优和满意涂片之间的区别。诊断解释的分析显示,良性和恶性病例合并的正确分类为92.5–95%(观察者内)或90-92.5%(观察者间),良性组中良性和非典型细胞之间存在差异,而良性组中可疑和恶性之间存在差异恶性群体。在恶性组中,有94%的病例通过RM被准确地细分。对于95%的幻灯片,使用RM观看的图像质量被评为适当(一般或良好)。结论:结果表明,使用RM对来自FNAB的直接涂片进行细胞学评估是可行的。遇到的问题包括评估具有浓厚,血性涂片和/或少量诊断细胞的病例所需的时间更长,以及难以识别神经内分泌分化和肝细胞癌的模拟物。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号