首页> 外文期刊>Journal of nuclear medicine technology >Lung Ventilation Studies: Surface Contamination Associated with Technetium-99m DTPA Aerosol
【24h】

Lung Ventilation Studies: Surface Contamination Associated with Technetium-99m DTPA Aerosol

机译:肺通气研究:与Technetium-99m DTPA气雾剂相关的表面污染

获取原文
           

摘要

Aerosol ventilation studies are assumed to have negligible room contamination when used correctly. This study was undertaken to determine whether a measurable amount of surface contamination is associated with routine technetium-99m DTPA aerosol ventilation studies. Three potential sources of contamination were evaluated: aerosol leakage related to the patients, aerosol leakage at the exhaust of the delivery system, and aerosol leakage related to operator error. A predefined protocol was used for setting up the apparatus and performing wipe tests. A GM survey was performed, and in all cases, no levels above background were detected. The results of the wipe tests, however, showed that 57% of patient studies had contamination underneath the exhaust of the device; 35% of the studies had floor contamination; and 39% of the studies contaminated the area adjacent to the patient.
机译:如果正确使用,则认为气雾通风研究对室内的污染可忽略不计。进行这项研究是为了确定可测量的表面污染量是否与常规tech 99m DTPA喷雾通风研究有关。评估了三种潜在的污染源:与患者有关的气溶胶泄漏,输送系统排气处的气溶胶泄漏以及与操作员错误有关的气溶胶泄漏。使用预定义的协议来设置设备和执行擦拭测试。进行了GM调查,在所有情况下均未检测到高于背景的水平。但是,擦拭测试的结果表明,有57%的患者研究在设备排气口下方有污染;因此,该测试结果尚未得到证实。 35%的研究有地板污染; 39%的研究污染了患者附近的区域。