Corneal thickness measurements with the Concerto on-board pachymeter

机译:使用协奏曲车载测厚仪测量角膜厚度

获取原文
           

摘要

Purpose: To assess the Concerto excimer laser on-board pachymeter (COP) measurements of the central corneal thickness (CCT), central stromal thickness (CST) and flap thickness (FT) in terms of repeatability and agreement with the Pentacam and ultrasound pachymetery. Methods: Patients undergoing photorefractive keratectomy (PRK), PRK with mitomycin-C (MMC), and laser in situ keratomileusis (LASIK) were enrolled in the study. All eyes had CCT measurement with the Pentacam, the COP, and ultrasound, preoperatively. In the LASIK group, the CST was measured intraoperatively with the COP and ultrasound, after removing the flap. Each measurement was done 3 times to study the repeatability, and we calculated the 95% limits of agreement (LoA) for paired readings. Results: The study sample comprised of 82 eyes of 41 patients. All three devices showed excellent repeatability with intraclass correlation coefficients between 0.946 and 0.993. Mean CCT was 546+/-31@mm with the COP, and 548+/-32@mm and 548+/-34@mm with the ultrasound and Pentacam, respectively. COP readings demonstrated high correlations with their paired ultrasound and Pentacam readings. The 95% LoA between COP and ultrasound were -16.6@mm to 12.0@mm for CCT, -25.6@mm to 26.2@mm for CST, and -29.5 to 21.3@mm for FT. The 95% LoA between COP and Pentacam CCT readings were -15.1@mm to 10.1@mm. Conclusions: COP generated repeatable readings that were highly correlated with their pair readings by the Pentacam and ultrasound. Although the agreement between COP and ultrasound was better with CCT measurements, the inter-device agreement for CST readings was not worse than that reported in other comparative studies of pachymeters.
机译:目的:在重复性方面以及与Pentacam和超声测厚仪的一致性方面,评估Concerto准分子激光车载测厚仪(COP)对中央角膜厚度(CCT),中央基质厚度(CST)和皮瓣厚度(FT)的测量。方法:接受光折射性角膜切除术(PRK),丝裂霉素C的PRK(MMC)和激光原位角膜磨镶术(LASIK)的患者入选。术前用Pentacam,COP和超声检查所有眼睛。 LASIK组在切除皮瓣后,在术中用COP和超声测量CST。每次测量均进行3次以研究可重复性,我们计算了配对读数的95%一致性极限(LoA)。结果:研究样本包括41例患者的82眼。所有这三种器件均显示出极好的可重复性,组内相关系数在0.946至0.993之间。 COP的平均CCT为546 +/- 31 @ mm,超声和Pentacam的CCT分别为548 +/- 32 @ mm和548 +/- 34 @ mm。 COP读数显示出与配对的超声和Pentacam读数高度相关。 COP和超声之间的95%LoA对于CCT为-16.6@mm至12.0@mm,对于CST为-25.6@mm至26.2@mm,对于FT为-29.5至21.3@mm。 COP和Pentacam CCT读数之间的95%LoA为-15.1@mm至10.1@mm。结论:COP产生的可重复读数与Pentacam和超声对其配对读数高度相关。尽管使用CCT测量,COP和超声之间的一致性更好,但是CST读数的设备间一致性并不比其他测厚仪的比较研究中的差。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号