首页> 外文期刊>Journal of Ophthalmic and Vision Research >Outcome of single-piece intraocular lens sulcus implantation following posterior capsular rupture during phacoemulsification
【24h】

Outcome of single-piece intraocular lens sulcus implantation following posterior capsular rupture during phacoemulsification

机译:白内障超声乳化术中后囊破裂后单件人工晶状体沟植入的结果

获取原文
           

摘要

Purpose: To assess the safety and outcome of single-piece posterior chamber intraocular lens (PC-IOL) implantation in the ciliary sulcus following posterior capsular rupture during cataract surgery. Methods: Patients with posterior capsular rupture during cataract surgery with a single-piece acrylic IOL implanted into the ciliary sulcus were studied. complete ocular examinations were performed after 6 months postoperatively. Results: Twenty-four eyes were included. Mean follow-up duration was 8.33 ± 2.33 months. There was no significant difference between preoperative and postoperative keratometric cylinder or intraocular pressure. Visual acuity of 87.50% of patients was ≥20/40 after surgery. complications included foveopathy (10 eyes), iris transillumination defect (4 eyes), iris chafing (2 eyes), pigmented keratic precipitate (KP) (4 eyes), clinical IOL tilt (6 eyes), endothelial pigment dusting (14 eyes), IOL pigment dusting (17 eyes), iris bowing (6 eyes), IOL decentration (4 eyes), and IOL tilt detected with ultrasonography biomicroscopy (UBM) (4 eyes). IOL pigment dusting was significantly higher in eyes with short axial lengths, high IOL power, small sulcus-to-sulcus (STS) diameter, large STS IOL diameter mismatch, and small anterior chamber depth and angle. Significant relationships were observed between pigmented KP with small STS diameter and large STS IOL diameter mismatch, UBM and clinical IOL tilt with large anterior chamber depth and between iris transillumination defect and STS IOL diameter mismatch. Conclusion: This implantation is associated with higher incidence of complications. Single-piece acrylic IOLs are not designed for sulcus implantation. However, they may be used in eyes with longer axial length if the 3-piece IOL is not available.
机译:目的:评估白内障手术后囊破裂后在睫状沟中单颗后房型人工晶状体(PC-IOL)植入的安全性和结果。方法:研究了在白内障手术中将单片丙烯酸人工晶状体植入睫状沟中后囊破裂的患者。术后6个月后进行全面的眼科检查。结果:包括二十四只眼睛。平均随访时间为8.33±2.33个月。术前和术后角膜测量圆柱度或眼压之间无显着差异。术后视力≥20/ 40为87.50%。并发症包括中央凹病(10眼),虹膜透照缺陷(4眼),虹膜擦伤(2眼),色素性角膜沉淀(KP)(4眼),临床IOL倾斜(6眼),内皮素粉尘(14眼),超声生物显微镜(UBM)检测到的IOL颜料粉尘(17眼),虹膜弯曲(6眼),IOL偏心(4眼)和IOL倾斜(4眼)。在短轴长,高IOL屈光度,小沟到沟(STS)直径,大的STS IOL直径不匹配以及小小的前房深度和前角的眼中,IOL色素粉尘显着更高。 STS直径较小且STS IOL直径不匹配较大的色素性KP,UBM与前房深度较大的临床IOL倾斜之间以及虹膜透照缺陷与STS IOL直径不匹配之间存在显着关系。结论:这种植入与并发症发生率更高有关。单件式丙烯酸人工晶状体不适用于沟植入。但是,如果没有三片式IOL,则可将它们用于更长的眼轴。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号