首页> 外文期刊>Journal of Obstetrics and Gynecology of India >Association of the Position of the Copper T 380A as Determined by the Ultrasonography Following its Insertion in the Immediate Postpartum Period with the Subsequent Complications: An Observational Study
【24h】

Association of the Position of the Copper T 380A as Determined by the Ultrasonography Following its Insertion in the Immediate Postpartum Period with the Subsequent Complications: An Observational Study

机译:产后立即插入的超声检查确定的铜T 380A位置与随后发生的并发症的关联:一项观察性研究

获取原文
           

摘要

Purpose Incorrectly placed copper T 380A leads to increased contraception failure. This study aimed to find an association between the ultrasonographic position of the copper T 380A in the immediate postpartum period and the adverse effects observed during the period of 6?months after its insertion. Methods This descriptive study was carried out in the Department of Obstetrics & Gynaecology of a tertiary-care-center of India from September 2011 to February 2013. The women eligible for immediate postpartum copper T 380A insertion with previous regular menstrual cycles for at least 6?months before the current pregnancy, and those who were willing for follow-up visits and had easy accessibility to the hospital, were recruited. A clinical evaluation and ultrasonographic assessment of Intra-Uterine-Contraceptive-Device (IUCD) after insertion was carried out after enrolment. The complications (expulsions, vaginal discharge, menstrual irregularity, and lower abdominal pain) were subsequently assessed during a 6-month follow-up period. The primary objective was the ultrasonographic assessment of the placement of IUCD immediately after insertion. The incidence of complications and their association with the presence of malposition was also studied. Results Hundred patients were evaluated during the study period. Forty-four (44?%) women were found to have malpositioned IUCDs on ultrasonographic evaluation done following insertion. The complications among the IUCD users included menstrual irregularity (27.17?%), pain in lower abdomen (20.65?%), vaginal discharge (7.6?%), and expulsions (9.7?%). The IUCD expulsions, menstrual irregularities, and pain were significantly more in patients with malpositions ( p
机译:目的铜T 380A放置不正确会导致避孕失败增加。这项研究的目的是在产后立即将铜T 380A的超声位置与插入后6个月内观察到的不良影响联系起来。方法该描述性研究于2011年9月至2013年2月在印度三级医疗中心的妇产科进行。这些妇女符合资格,即刻接受产后立即铜T 380A的治疗,且之前的月经周期至少为6?招募了那些在当前妊娠前几个月,以及愿意进行随访并易于出入医院的人。入院后进行宫内避孕器(IUCD)的临床评估和超声检查。随后在6个月的随访期内评估了并发症(排出,白带,月经不调和下腹部疼痛)。主要目的是在插入后立即超声检查IUCD的位置。还研究了并发症的发生率及其与错位的关系。结果研究期间对一百名患者进行了评估。在插入后进行的超声检查中发现四十四(44%)名妇女患有错位的IUCD。 IUCD使用者的并发症包括月经不调(27.17%),小腹疼痛(20.65%),白带(7.6%)和驱逐(9.7%)。错位患者的IUCD排出,月经不调和疼痛明显增加(p <?0.05)。结论IUCD植入后立即放置错位很常见,并且在随访过程中与更多并发症显着相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号