Comparison of Operator Workloads Associated with the Single-unit Anyfusion? Pump and the Changeover from a Syringe Pump to an Infusion Pump

机译:比较与单单元注入相关的操作员工作量?泵和从注射泵到输液泵的转换

获取原文
       

摘要

Background A changeover from a syringe pump to an infusion pump may transiently interrupt drug administration and result in medication errors. A newly developed infusion device (Anyfusion ? ) that combines the functions of an infusion pump and a syringe pump in a single unit was recently commercialized. This study compared the operator workloads associated with the Anyfusion ? pump and with the conventional method using two infusion devices (a syringe pump and an infusion pump). Methods This was a prospective, randomized, crossover-designed simulation study using an imitation arm with an intravascular line. We compared the two methods in terms of total execution time, total number of button clicks, and subjective difficulty using a numerical rating scale with a score from 0 (extremely easy) to 10 (extremely difficult). Results Twenty-two nurses successfully performed both interventions according to the allocated sequence. Total execution times did not differ between the two methods (129.5 ± 23.2 seconds for the conventional method vs. 121.2 ± 24.3 seconds for the Anyfusion ? method; P = 0.244), although the total number of clicks was significantly fewer using the Anyfusion ? than the conventional method (median [interquartile range]: 10.0 [9.0–12.0] vs. 21.0 [20.0–25.0], respectively; P 0.001). Participants rated the Anyfusion ? method as easier than the conventional method (1.7 ± 1.2 vs. 3.6 ± 1.6; P 0.001, respectively). Conclusion The introduction of Anyfusion ? lessened the workload of practitioners required by the changeover process, which might reduce the risk of medication errors and subsequent patient harm.
机译:背景技术从注射泵到输液泵的转换可能会暂时中断药物的给药并导致用药错误。最近,一种新开发的输液装置(Anyfusion?)在一个单元中将输液泵和注射泵的功能结合在一起。这项研究比较了与Anyfusion?相关的操作员工作量。泵,并采用传统方法使用两个输液装置(注射泵和输液泵)。方法这是一项前瞻性,随机,交叉设计的模拟研究,使用带有血管内线的仿制臂。我们使用总分从0(非常容易)到10(非常困难)的数字量表对总执行时间,按钮单击总数和主观难度进行了比较。结果22名护士按照分配的顺序成功进行了两种干预。两种方法的总执行时间没有差异(传统方法为129.5±23.2秒,而Anyfusion™方法为121.2±24.3秒; P = 0.244),尽管使用Anyfusion®方法的总点击次数明显减少。比传统方法(中位数[四分位数间距]:分别为10.0 [9.0-12.0]和21.0 [20.0-25.0]; P <0.001)。参与者对Anyfusion进行了评分?方法比传统方法更容易(分别为1.7±1.2和3.6±1.6; P <0.001)。结论Anyfusion的引入?减轻了转换过程所需的从业人员的工作量,这可能减少用药错误和随后对患者造成伤害的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号