Background: Rose Bengal is a common test for serologic diagnosis of brucellosis. The aim of this study was to evaluate the agreement rate between modified rose Bengal, rose Bengal and rapid Wright tests for detection of antibody positive serum samples. Methods: C ross section study was designed. 941 serum sample of patients referred to the central medical laboratory of Kermanshah, were evaluated by rose Bengal, modified rose Bengal and rapid Wright, using convenient sampling method. Positive samples were confirmed and their titers were defined by Wright agglutination test. Results: The number of positive serum samples with modified rose Bengal was two fold higher than conventional rose Bengal test (P<0.001), which included all positive samples with rose Bengal. On the other hand, although the number of positive diagnosed serum samples with modified rose Bengal were nearly two times more than Wright test (P<0.001), but it did not include all positive samples detected by Wright test. All three tests showed acceptable agreement rate (k≥0.583). Conclusion: Results of this study confirmed that modified rose Bengal able to detect more positive serum sample than conventional rose Bengal and it would be substituted rose Bengal. However, the rapid Wright test should be used aside with modified rose Bengal, because it could not cover all positive samples detected by rapid Wright test.
机译:背景:孟加拉红是布鲁氏菌病血清学诊断的常用检测方法。这项研究的目的是评估改良的玫瑰孟加拉,玫瑰孟加拉和快速赖特测试之间用于检测抗体阳性血清样品的一致率。方法:设计横断面研究。玫瑰科,改良孟加拉科和快速赖特使用方便的采样方法对转诊至克曼沙赫中央医学实验室的941名患者的血清样本进行了评估。确认阳性样品,并通过赖特凝集试验确定其滴度。结果:修饰的玫瑰红阳性血清样品数量是常规玫瑰红孟加拉测试的两倍(P <0.001),其中包括所有阳性的玫瑰红样品。另一方面,尽管经过诊断的改良孟加拉玫瑰红血清样本的阳性数几乎是Wright试验的两倍(P <0.001),但它不包括Wright试验检测到的所有阳性样本。所有三个测试均显示可接受的一致率(k≥0.583)。结论:这项研究的结果证实,与传统的玫瑰红相比,改良的玫瑰红能够检测到更多的阳性血清样品,并且可以替代玫瑰红。但是,快速Wright试验应与改良的玫瑰红孟加拉试验同时使用,因为它不能涵盖通过快速Wright试验检测到的所有阳性样品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号