Reliability & linearity of an electronic body protector employed in taekwondo games: a preliminary study

机译:跆拳道比赛中使用的电子身体保护器的可靠性和线性度:初步研究

获取原文
       

摘要

An officialelectronic body protector (EBP) requires both, the necessary degree of accuracyand consistency in securing the same result under similar conditions. Thepurpose of this study was to assess the repeatability and linearity of a taekwondoEBP. A commercially available EBP that registers the energy (E) of a hit inJoules was placed unfolded on a hard non-deformable surface. Ten potential"hit" areas were marked on the EBP's surface. To simulate kickingconditions a 4 kg iron shot attached to a switch operated electromagnet wassystematically released against the EBP from three randomly selected heights(1.78m, 1.92m, and 2.00m). The shot was released 5 times repeatedly from eachheight on each of the 10 areas. The procedure was repeated after a 30mininterval. Reliability was assessed by the test-retest method using Chronbach'salpha, Guttman split half and ICC, and the coefficient of variation (%CV). Theoverall (10 sites pooled together) CV was 4.8%. Τhe CV’s for the three heightsof release were 5.47%, 4.77%, and 4.18%, respectively. For the 10 separateanalyses (one for each of the 10 EBP sites) CV ranged from 2.5% to 11.6%. Forthe 10 separate analyses (one for each of the 10 trials) CV ranged from 6.8% to11.6%. The overall reliability between the 30 trials (across the three heightsof release) was: Chronbach's α = 0.979, single measure ICC = 0.572, averagemeasure ICC = 0.976 (p0.001). Testing revealed that the inter-trial andinter-site reliability of the EBP is poor. Further research is required intesting the reliability of a variety of body protectors used in officialcompetitions today so as to assure fairness among contestants.
机译:官方的电子体保护器(EBP)要求在相似条件下确保相同结果时必须具有必要的准确性和一致性。这项研究的目的是评估跆拳道EBP的可重复性和线性。记录击中焦耳能量(E)的市售EBP展开在坚硬的不可变形表面上。在EBP的表面上标记了十个潜在的“击中”区域。为了模拟踢球情况,从三个随机选择的高度(1.78m,1.92m和2.00m)有针对性地向EBP系统释放了连接到开关操作的电磁体上的4 kg铁弹。在10个区域中的每个高度上,该镜头均被重复释放5次。 30分钟间隔后重复该过程。通过使用Chronbach'salpha,Guttman split half和ICC以及变异系数(%CV)的重测方法评估可靠性。总体(10个网站集中在一起)的简历率为4.8%。这三个释放高度的简历分别为5.47%,4.77%和4.18%。对于10个单独的分析(10个EBP位点中的每一个位点),CV范围从2.5%到11.6%。对于10个单独的分析(10个试验中的每个试验之一),CV范围为6.8%至11.6%。在30个试验之间(横跨三个释放高度)的总体可靠性为:克伦巴赫α= 0.979,单项ICC = 0.572,平均ICC = 0.976(p <0.001)。测试表明,EBP在审判之间和审判地点之间的可靠性很差。需要进行进一步的研究以检验当今官方比赛中使用的各种护具的可靠性,以确保参赛者之间的公平。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号