首页> 外文期刊>Journal of Engineering and Technological Sciences >Modification of Attenuation Rate in Range Normalization of Echo Levels for Obtaining Frequency-dependent Intensity Data from 0.6MHz and 1.0MHz Devices
【24h】

Modification of Attenuation Rate in Range Normalization of Echo Levels for Obtaining Frequency-dependent Intensity Data from 0.6MHz and 1.0MHz Devices

机译:在回波电平范围归一化中衰减速率的修改,以从0.6MHz和1.0MHz器件获得频率相关的强度数据

获取原文
           

摘要

This investigation aims to propose an attenuation rate for range normalization of echo amplitudes recorded by an acoustic backscattering instrument working at a frequency of 1.0 MHz. The intention of the use of such an attenuation rate is to obtain equal echo levels when using a device from the same family of products with a different working frequency, i.e. a 0.6 MHz instrument, at an identical site. This work is based on a field experiment with a 1.0 MHz Acoustic Wave and Current (AWAC) profiler and a 0.6 MHz Aquadopp profiler. Both profilers were deployed upward, side-by-side in the Semak Daun reef lagoon, Seribu Islands, Java Sea, Indonesia. It was found that the proposed attenuation rate for the 1.0 MHz instrument was one-order magnitude higher with respect to the one used for the 0.6 MHz instrument, and logarithmically depth dependent. The proposed attenuation rate for the 1.0 MHz AWAC is –7.925log(R) + 8.551, with R is the slant range from the transducers to the measured layer. Accordingly, the overall agreement between the 1.0 MHz AWAC echo amplitude and the one recorded by the 0.6 MHz Aquadopp was improved by 18dB, which is quite significant considering that the average echo amplitude discrepancy recorded by each transducer was 2.4dB.
机译:这项研究的目的是提出一种衰减率,用于对以1.0 MHz频率工作的声学反向散射仪记录的回波幅度进行范围归一化。使用这种衰减率的目的是,在同一地点使用来自同一系列产品的具有不同工作频率的设备(即0.6 MHz仪器)时,获得相同的回波水平。这项工作基于使用1.0 MHz声波和电流(AWAC)轮廓仪和0.6 MHz Aquadopp轮廓仪的现场实验。两种探查仪并排部署在印度尼西亚爪哇海的实里布群岛的塞马克道恩礁泻湖中。发现1.0 MHz仪器的建议衰减率比0.6 MHz仪器所用的衰减率高一个数量级,并且对数依赖于深度。 1.0 MHz AWAC的建议衰减率为–7.925log(R)+ 8.551,其中R为从传感器到被测层的倾斜范围。因此,1.0 MHz AWAC回波振幅与0.6 MHz Aquadopp记录的回波振幅之间的总体一致性提高了18dB,考虑到每个换能器记录的平均回波振幅差异为2.4dB,这是非常有意义的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号