Introduction: The use of ultrasound images for analyzing muscle quality and size is continuing to grow in the literature. However, many of these manuscripts fail to properly describe their measurement techniques and steps involved in analyzing ultrasound images. Aim of this study: To evaluate the intra- and inter-rater reliability of the steps involved when analyzing ultrasound images to measure cross-sectional area and echo intensity. Material and methods: Twenty ultrasound images of the rectus femoris and vastus lateralis images were blinded and replicated, and then analyzed by experienced raters. The raters then were asked to analyze the images using open-source software for scaling measurements, subcutaneous fat thickness, cross-sectional area, and echo intensity. Matched image values for each measurement where compared for intra- and inter-rater reliability. Results: Intra-rater reliability ranged from fair (ICC3,1 = 0.32) to high (0.98), with echo intensity values being the least reliable (>0.55), and scaling and depth measurements being the most reliable (<0.85). Inter-rater reliability ranged from good (0.77) to high (0.97). Conclusion: Ultrasound-derived measures of cross-sectional area and echo intensity can be measured reliably, with echo intensity being the most difficult to replicate. However, reliability measures are unique to the rater and study and, therefore, should be clearly reported in every paper.
机译:简介:使用超声图像进行分析肌肉质量和大小正在继续在文献中生长。然而,许多这些稿件未能正确描述其测量技术和参与分析超声图像的步骤。本研究的目的:评估在分析超声图像时涉及的步骤的帧内间可靠性,以测量横截面积和回声强度。材料和方法:盲目和复制20个超声图像的直肠股骨和夸张的侧面图像,然后通过经验丰富的评估者分析。然后要求评估者使用开源软件分析图像以进行缩放测量,皮下脂肪厚度,横截面积和回波强度。与帧内和帧间间可靠性相比,每次测量的匹配图像值。结果:帧内可靠性范围从公平(ICC3,1 = 0.32)到高(0.98),回声强度值是最不可靠的(> 0.55),并缩放和深度测量是最可靠的(<0.85)。帧间间可靠性从良好(0.77)到高(0.97)。结论:可以可靠地测量超声波突出的横截面积和回波强度的测量,回声强度是最难以复制的。然而,可靠性措施对评估者而言是独一无二的,因此应该在每篇论文中清楚地报告。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号