A Methodology to Link the Internal Heat Gains from Lighting to the Global Consumption for the Energy Certification of Buildings in Italy

机译:一种将照明的内部热量与全球建筑能耗联系起来的方法,以实现意大利建筑的能源认证

获取原文
       

摘要

This paper critically discusses the procedure prescribed by the Italian Technical Standards to account for the internal gains in the calculation of the energy performance indices for a building. This procedure is based on a tabular value set depending on the building usage only (e.g., 6 W/m2 for office buildings), independently of the site and of the controls for blinds and lighting systems. Instead, the paper proposes a new procedure, which relies on the lighting energy numerical indicator (LENI) according to the European Standard EN 15193:2007. Basically, the procedure consists of the following steps: 1) internal gains from lighting are calculated accounting for the integration between electric appliances and daylighting; 2) these gains are summed to the internal gains from occupants and appliances; 3) the global gains are used as input data to calculate the energy performance indices for an office building (for space heating, space cooling, and lighting consumption) following the Italian Technical Standards. The office building which was used as case-study is the Department of Energy of the Politecnico di Torino. This was assumed to be located both in Turin (northern Italy) and in Palermo (southern Italy). In the study, the use of a manual on/off switch and of a photodimming sensor was also compared. For each configuration, the single and the global energy performance indices were calculated comparing two approaches to calculate the internal gains (Italian standard vs. new proposed procedure): a shift of one energy class for the building energy label was observed depending on the approach, which was used.
机译:本文认真讨论了意大利技术标准规定的程序,该程序考虑了建筑物能源性能指标计算中的内部收益。此过程基于表格值,该表格值仅取决于建筑物的使用情况(例如,办公楼为6 W / m 2 ),与站点以及百叶窗和照明系统的控件无关。取而代之的是,本文提出了一种新程序,该程序依赖于根据欧洲标准EN 15193:2007的照明能量数字指示器(LENI)。基本上,该过程包括以下步骤:1)计算照明的内部收益,考虑到电器和采光之间的集成; 2)这些收益加在一起是来自居住者和家用电器的内部收益; 3)将全球收益用作输入数据,以根据意大利技术标准计算办公楼的能源绩效指数(用于空间供暖,空间制冷和照明消耗)。用作案例研究的办公大楼是都灵理工大学能源部。假定它位于都灵(意大利北部)和巴勒莫(意大利南部)。在这项研究中,还比较了手动开/关开关和光暗传感器的使用。对于每种配置,通过比较两种计算内部收益的方法(意大利标准与新提议的程序),计算了单一和全球能源性能指标:根据方法,观察到建筑能源标签的一种能源类别发生了变化,被使用了。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号