...
首页> 外文期刊>Journal of Applied Oral Science >Effects of in-office bleaching agent combined with different desensitizing agents on enamel
【24h】

Effects of in-office bleaching agent combined with different desensitizing agents on enamel

机译:办公室漂白剂与不同脱敏剂的结合对牙釉质的影响

获取原文

摘要

Objective: To analyze color change, microhardness and chemical composition of enamel bleached with in-office bleaching agent with different desensitizing application protocols. Materials and Methods: One hundred and seventeen polished anterior human enamel surfaces were obtained and randomly divided into nine groups (n = 13). After recording initial color, microhardness and chemical composition, the bleaching treatments were performed as G1: Signal Professional White Now POWDER&LIQUID FAST 38% Hydrogen peroxide(S); G2: S+Flor Opal/0.5% fluoride ion(F); G3: S+GC Tooth Mousse/Casein Phosphopeptide-Amorphous Calcium Phosphate (CPP-ACP) paste(TM); G4: S+UltraEZ/3% potassium nitrate&0.11% fluoride(U); G5: S+Signal Professional SENSITIVE PHASE 1/30% Nano-Hydroxyapatite (n-HAP) suspension(SP); G6: S-F mixture; G7: S-TM mixture; G8: S-U mixture; G9: S-SP mixture. Color, microhardness and chemical composition measurements were repeated after 1 and 14 days. The percentage of microhardness loss (PML) was calculated 1 and 14 days after bleaching. Data were analyzed with ANOVA, Welch ANOVA, Tukey and Dunnett T3 tests (p0.05). Results: Color change was observed in all groups. The highest ΔE was observed at G7 after 1 day, and ΔE at G8 was the highest after 14 days (p0.05). A decrease in microhardness was observed in all groups except G6 and G7 after 1 day. The microhardness of all groups increased after 14 days in comparison with 1 day after bleaching (p0.05). PML was observed in all groups except G6 and G7 after bleaching and none of the groups showed PML after 14 days. No significant changes were observed after bleaching at Ca and P levels and Ca/P ratios at 1 or 14 days after bleaching (p0.05). F mass increased only in G2 and G6, 1 day after bleaching (p0.05). Conclusions: The use of desensitizing agents containing fluoride, CPP-ACP, potassium nitrate or n-HAP after in-office bleaching or mixed in bleaching agent did not inhibit the bleaching effect. However, they all recovered microhardness of enamel 14 days after in-office bleaching.
机译:目的:分析在不同脱敏应用方案下使用办公室漂白剂漂白的搪瓷的颜色变化,显微硬度和化学成分。材料和方法:获得一百一十七个抛光的人类釉质前表面,并将其随机分为9组(n = 13)。记录初始颜色,显微硬度和化学成分后,按G1进行漂白处理:Signal Professional White Now POWDER&LIQUID FAST 38%过氧化氢; G2:S +氟蛋白石/0.5%氟离子(F); G3:S + GC牙慕斯/酪蛋白磷酸肽-无定形磷酸钙(CPP-ACP)糊剂; G4:S + UltraEZ / 3%硝酸钾和0.11%氟化物(U); G5:S + Signal Professional SENSITIVE PHASE 1/30%纳米羟基磷灰石(n-HAP)悬浮液(SP); G6:S-F混合物; G7:S-TM混合物; G8:S-U混合物; G9:S-SP混合物。在1天和14天后重复测量颜色,显微硬度和化学成分。漂白后1天和14天计算出显微硬度损失(PML)的百分比。数据用ANOVA,Welch ANOVA,Tukey和Dunnett T3测试进行分析(p <0.05)。结果:在所有组中均观察到颜色变化。 1天后在G7处观察到最高的ΔE,而14天后在G8处的ΔE最高(p <0.05)。 1天后,除G6和G7外,所有组的显微硬度均降低。与漂白后1天相比,所有组在14天后的显微硬度都有所提高(p> 0.05)。漂白后除G6和G7外,所有组均观察到PML,14天后均未显示PML。在漂白后1或14天,Ca和P水平以及Ca / P比在漂白后均未观察到显着变化(p> 0.05)。漂白后1天,F质量仅在G2和G6中增加(p <0.05)。结论:在办公室漂白后或与漂白剂混合使用含有氟化物,CPP-ACP,硝酸钾或正HAP的脱敏剂不会抑制漂白效果。但是,他们在办公室漂白后14天都能恢复搪瓷的显微硬度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号