Validation of an experimental polyurethane model for biomechanical studies on implant supported prosthesis - tension tests

机译:用于植入物支持的假体生物力学研究的实验性聚氨酯模型的验证-拉伸测试

获取原文

摘要

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
机译:目的:人骨的复杂性和异质性以及道德问题经常阻碍临床试验的发展。这项体外研究的目的是通过拉伸试验确定聚氨酯各向同性实验模型的弹性模量,将结果与文献报道的下颌骨进行比较,以验证使用这种模型来代替下颌骨。下颌骨的生物力学研究。材料与方法:根据聚氨酯试剂的比例(A / B)(PU-1:1 / 0.5,PU-2:1/1,PU),将45个聚氨酯试样分为3组,每组15个试样-3:1 / 1.5)。结果:在每个实验组中进行了拉伸试验,发现PU-1的弹性模量值为192.98 MPa(SD = 57.20),PU-2为347.90 MPa(SD = 109.54),PU-1为304.64 MPa(SD = 25.48)。 PU-3。结论:建立实验模型的选择浓度为1/1。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号