Passive cooling techniques are cost effective and reliable methods of cooling remote radio heads (RRH). This paper investigates the plausibility of a passive cooling technique involving exchanging warm air, from the internal cavity of RRHs, with fresh ambient air, to reduce the operating temperature using natural convection across air filters. The results indicate that, an internal air filter tube structure, with width of the enclosure, running vertically up the middle of an RRH, along with 4 pleat filter sides (2.0 ± 0.5 cm separation) provides the most effective outdoor suitable setup out of those examined. This provides a reduction in temperature of 3.9°K ± 0.4°K in the PA and 4.0°K ± 0.4°K in the radio, and a reduction in mass of 0.45 ± 0.05 kg, and is capable of withstanding water ingress and corrosive conditions including wind driven rain and salt fog.
机译:被动冷却技术是冷却远程无线电头(RRH)的经济高效且可靠的方法。本文研究了一种被动冷却技术的可行性,该技术涉及通过将RRH内部腔中的热空气与新鲜的环境空气交换来使用跨空气过滤器的自然对流来降低运行温度。结果表明,内部空气滤清器管结构的外壳宽度沿RRH的中间垂直向上延伸,并带有4个褶式滤清器侧面(间隔为2.0±0.5厘米),是其中最有效的室外合适装置检查。这样可以将PA中的温度降低3.9°K±0.4°K,将无线电设备中的温度降低4.0°K±0.4°K,质量降低0.45±0.05 kg,并且能够承受进水和腐蚀性条件包括风雨和盐雾。