Effectiveness of Technolas torsional eye tracking system on visual outcomes after photorefractive keratectomy

机译:Technolas扭转眼动追踪系统对屈光性角膜切除术后视力结果的有效性

获取原文
           

摘要

Purpose To investigate the efficacy of Technolas 217Z eye tracking system ( torsional component ) in corneal surface irregularity and high order aberrations (HOAs) after photorefractive keratectomy Methods Patients with compound myopic astigmatism among persons demanding refractive surgery in Khatam-al-Anbia Eye Hospital with the mean age of 29 years were enrolled in this double-blind randomized interventional study. The mean spherical equivalent (SE) of refractive error was ?4.75 diopters(D) (range: ?1.5 to ?7.0), and the mean astigmatism was 3 D (range:1.0–4). Many studies were performed for each patient including: A complete eye examination, visual acuity and Monocular contrast sensitivity evaluation, and refraction. Corneal topography, Orbscan II, and wavefront aberrometry were conducted. One eye was randomly assigned for aspheric treatment and applying eye tracking system. The other eye was treated without torsional eye tracking system. The outcome measures were uncorrected visual acuity (UCVA), best corrected visual acuity (BCVA), contrast sensitivity, corneal irregularity index in 3?mm and 5?mm optical zones in Orbscan II, and mean total HOAs at the 6-monthvisit. Results Fifty eyes of 25 patients were enrolled. Mean UCVA was improved significantly in both the study and control groups in the 6-month post-operative follow-up. There was no significant difference between the 2 groups in UCVA and BCVA ( P ?=?0.185 and P ?=?0.176, respectively). Total HOAs increased in both groups after PRK. However, they were lower in eyes treated with the eye tracking system ( P ?
机译:目的探讨Technolas 217Z眼动追踪系统(扭转组件)在角膜屈光性角膜切除术后角膜表面不规则和高阶像差(HOA)中的疗效。方法该双盲随机干预研究的平均年龄为29岁。屈光不正的平均球当量(SE)为?4.75屈光度(D)(范围:?1.5至?7.0),平均散光为3 D(范围:1.0–4)。针对每位患者进行了许多研究,包括:完整的眼睛检查,视敏度和单眼对比敏感度评估以及屈光度。进行角膜地形图,Orbscan II和波前像差法。随机分配一只眼睛进行非球面治疗并应用眼睛跟踪系统。另一只眼未经扭转眼动追踪系统治疗。结果指标为Orbscan II中3?mm和5?mm光学区域的未矫正视敏度(UCVA),最佳矫正视敏度(BCVA),对比敏感度,角膜不规则指数,以及在6个月访视时的平均总HOA。结果25例患者共50只眼。在术后6个月的随访中,研究组和对照组的平均UCVA均得到显着改善。两组在UCVA和BCVA之间没有显着差异(分别为P?=?0.185和P?=?0.176)。 PRK后两组的总HOA增加。但是,在用眼动追踪系统治疗的眼睛中它们较低(P≤0.001)。在研究组中,Orbscan II中3?mm和5?mm中心区的角膜不规则指数显着降低(分别为P?=?0.045和P?=?0.031)。两组的对比敏感度函数无差异(P≥0.15)。结论我们的研究结果表明,使用“ Technolas 217z”眼动仪(Bausch和Lomb Advanced)可以使角膜前表面更规则。因此,我们建议将其用于表面激光屈光手术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号