首页> 外文期刊>Journal of Diabetes Science and Technology >Patient Perceptions of Different Lancing Sites for Self-Monitoring of Blood Glucose: A Comparison of Fingertip Site with Palm Site Using the OneTouch? Ultra? Blood Glucose Monitoring System
【24h】

Patient Perceptions of Different Lancing Sites for Self-Monitoring of Blood Glucose: A Comparison of Fingertip Site with Palm Site Using the OneTouch? Ultra? Blood Glucose Monitoring System

机译:自我监测血糖的不同刺血部位的患者知觉:使用OneTouch的指尖部位与手掌部位的比较?超?血糖监测系统

获取原文
           

摘要

Background: Alternate-site testing (AST) for self-monitoring of blood glucose leads to improved glycemic control for treatment of diabetes mellitus. The aim of this randomized, open-label, two-period, crossover study was to compare the comfort of two different lancing sites, fingertip and palm sites, for AST in diabetes patients. Methods: Patients injected insulin four times a day. Self-monitoring of blood glucose was carried out more than thrice daily with fingertip measurements for at least three months using apparatuses except the OneTouch? Ultra? Blood Glucose Monitoring System (OneTouch) before examination. The comfort of two lancing sites using OneTouch were compared. In two randomized groups that used one fingertip lancing site for one week followed by the alternate lancing site for another week, patients completed 11-item questionnaires assessing usability of the site before and after each week. Each item was scored on a visual analogue scale from ?100 (most negative) to +100 (most positive). Results: Most patients desired to continue AST, which was insignificantly different between the two lancing sites (fingertip and palm AST) in 43 diabetes patients aged 57.3 ± 13.8 years, body mass index of 23.1 ± 2.5 kg/m~(2), diabetes duration of 19.6 ± 9.7 years, and hemoglobin A1c of 7.4 ± 1.1%. However, patients were less ( p < .01) satisfied with using the palm lancing site as compared to the fingertip lancing site because of difficulties in inserting the needle, drawing blood samples, and applying enough blood into the test strip. Conclusions: These results suggest that patients desire to use the palm for AST, but more technological advances in AST of a palm site is required to reduce patient discomfort.
机译:背景:用于血糖自我监测的交替现场检测(AST)可以改善糖尿病患者的血糖控制。这项随机,开放标签,两期,交叉研究的目的是比较糖尿病患者AST的两个不同切缝部位(指尖和手掌部位)的舒适度。方法:患者每天注射胰岛素四次。使用OneTouch?以外的设备,每天至少用手指进行三次自我血糖监测至少三个月,进行三次。超?检查前的血糖监测系统(OneTouch)。比较了使用OneTouch的两个采血部位的舒适度。在两个使用一个指尖采血部位一周,然后使用另一个采血部位另一个星期的随机分组中,患者在每周之前和之后完成了11项问卷调查,以评估该部位的可用性。每个项目的视觉模拟评分从100分(最负)到+100分(最正)。结果:大多数患者希望继续AST,在43个57.3±13.8岁,体重指数为23.1±2.5 kg / m〜(2),糖尿病的糖尿病患者中,两个穿刺部位(指尖和手掌AST)之间无显着差异持续时间为19.6±9.7年,血红蛋白A1c为7.4±1.1%。但是,与使用指尖刺破部位相比,患者对使用手掌刺破部位的满意度较低(p <.01),因为难以插入针头,抽取血液样本以及将足够的血液注入测试条。结论:这些结果表明患者希望使用手掌进行AST,但是需要更多技术进步以减少患者的不适感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号