Background Blood transfusion is a pathway for the transmission of blood‐borne pathogens such as human immunodeficiency virus (HIV) and hepatitis B virus (HBV) from donors to recipients in most countries in sub‐Saharan Africa, including Gabon. The study aimed to compare the performance of four rapid diagnostic tests (RDTs: Alere DETERMINE, BIOSYNEX Exacto Pro HIV, MEDIFF HIV 1&2, and BIOSYNEX IMMUNOQUICK HBsAg) with results of 4th‐generation immunoenzymatic assays COBAS 6000 e601 and EVOLIS BioRad for the detection of HIV and hepatitis B surface antigen (HBsAg) in blood donors in Libreville, Gabon. Methods Reactive and nonreactive blood samples for HIV and HBsAg were selected using fourth‐generation ELISA COBAS 6000 e601 and EVOLIS BioRad. The sensitivities of RDTs were calculated using Epi Info version 6.04dfr (CDC, Atlanta, USA). Results Sensitivities for the detection of HIV in blood donors were 90.9% for Alere DETERMINE, 81.8% for BIOSYNEX Exacto Pro HIV, and 81.8% for MEDIFF HIV 1&2 Serum/sang Total Cassette compared with COBAS 6000 e601. The sensitivity of Alere DETERMINE compared to the semi‐automated ELISA Bio‐Rad for HIV detection was 65.6%. The sensitivity of BIOSYNEX IMMUNOQUICK HBsAg compared to ELISA tests for the detection of HBsAg was 78.0%. The specificity of all RDTs for the detection of HIV and HBsAg was 100%. Conclusion Alere DETERMINE HIV‐1/2, MEDIFF HIV 1&2 Serum/sang Total Cassette, BIOSYNEX Exacto Pro HIV, and BIOSYNEX IMMUNOQUICK HBsAg are not recommended for determining whether donors qualify to donate blood because of their low sensitivity for the detection of HIV antibodies and HBsAg in blood donors in Gabon.
机译:背景技术输血是撒哈拉以南非洲大多数国家(包括加蓬)将血源性病原体(例如人类免疫缺陷病毒(HIV)和乙型肝炎病毒(HBV))从供体传播到接受者的途径。这项研究旨在比较四种快速诊断测试(RDT:Alere DETERMINE,BIOSYNEX Exacto Pro HIV,MEDIFF HIV 1&2和BIOSYNEX IMMUNOQUICK HBsAg)的性能与第四代免疫酶分析COBAS 6000 e601和EVOLIS BioRad的检测结果加蓬利伯维尔的献血者中的HIV和乙肝表面抗原(HBsAg)。方法使用第四代ELISA COBAS 6000 e601和EVOLIS BioRad选择HIV和HBsAg的反应性和非反应性血液样本。使用Epi Info版本6.04dfr(CDC,美国亚特兰大)计算RDT的灵敏度。结果与COBAS 6000 e601相比,献血者中Alere DETERMINE的检测灵敏度为90.9%,BIOSYNEX Exacto Pro HIV的检测灵敏度为81.8%,MEDIFF HIV 1&2血清/桑氏总检测盒的灵敏度为81.8%。与半自动ELISA Bio-Rad相比,Alere DETERMINE对HIV检测的敏感性为65.6%。与ELISA试验相比,BIOSYNEX IMMUNOQUICK HBsAg对HBsAg的检测灵敏度为78.0%。所有RDT对检测HIV和HBsAg的特异性均为100%。结论不建议使用Alere DETERMINE HIV-1,MEDIFF HIV 1&2血清/桑氏总检测盒,BIOSYNEX Exacto Pro HIV和BIOSYNEX IMMUNOQUICK HBsAg来确定捐赠者是否有资格献血,因为它们对HIV抗体和加蓬献血者体内的HBsAg。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号