...
首页> 外文期刊>Journal of clinical laboratory analysis. >Assessment of rapid diagnostic tests and fourth‐generation Enzyme‐Linked Immunosorbent Assays in the screening of Human Immunodeficiency and Hepatitis B virus infections among first‐time blood donors in Libreville (Gabon)
【24h】

Assessment of rapid diagnostic tests and fourth‐generation Enzyme‐Linked Immunosorbent Assays in the screening of Human Immunodeficiency and Hepatitis B virus infections among first‐time blood donors in Libreville (Gabon)

机译:在Libleville(加蓬)筛选人体免疫缺陷和乙型肝炎病毒感染的筛选中评估快速诊断试验和第四代酶联免疫吸附试验

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Abstract Background Blood transfusion is a pathway for the transmission of blood‐borne pathogens such as human immunodeficiency virus (HIV) and hepatitis B virus (HBV) from donors to recipients in most countries in sub‐Saharan Africa, including Gabon. The study aimed to compare the performance of four rapid diagnostic tests (RDTs: Alere DETERMINE, BIOSYNEX Exacto Pro HIV, MEDIFF HIV 1&2, and BIOSYNEX IMMUNOQUICK HBsAg) with results of 4th‐generation immunoenzymatic assays COBAS 6000 e601 and EVOLIS BioRad for the detection of HIV and hepatitis B surface antigen (HBsAg) in blood donors in Libreville, Gabon. Methods Reactive and nonreactive blood samples for HIV and HBsAg were selected using fourth‐generation ELISA COBAS 6000 e601 and EVOLIS BioRad. The sensitivities of RDTs were calculated using Epi Info version 6.04dfr (CDC, Atlanta, USA). Results Sensitivities for the detection of HIV in blood donors were 90.9% for Alere DETERMINE, 81.8% for BIOSYNEX Exacto Pro HIV, and 81.8% for MEDIFF HIV 1&2 Serum/sang Total Cassette compared with COBAS 6000 e601. The sensitivity of Alere DETERMINE compared to the semi‐automated ELISA Bio‐Rad for HIV detection was 65.6%. The sensitivity of BIOSYNEX IMMUNOQUICK HBsAg compared to ELISA tests for the detection of HBsAg was 78.0%. The specificity of all RDTs for the detection of HIV and HBsAg was 100%. Conclusion Alere DETERMINE HIV‐1/2, MEDIFF HIV 1&2 Serum/sang Total Cassette, BIOSYNEX Exacto Pro HIV, and BIOSYNEX IMMUNOQUICK HBsAg are not recommended for determining whether donors qualify to donate blood because of their low sensitivity for the detection of HIV antibodies and HBsAg in blood donors in Gabon.
机译:摘要背景输血是从撒哈拉以南非洲的大多数国家,包括加蓬的大多数国家的捐献者到受者的人体免疫缺陷病毒(HIV)和乙型肝炎病毒(HBV)等血型病原体的途径。该研究旨在比较四种快速诊断测试的性能(RDTS:Alere确定,Biosynex Beactiono Pro Hiv,Mediff HIV 1& 2,和Biosynex免疫Quick HBsAg)具有第4代免疫酶测定Cobas 6000 E601和Evolis Biorad的结果Gigleville献血者血液供体中HIV和乙型肝炎表面抗原(HBsAg)的检测。方法采用第四代ELISA COBAS 6000 E601和EVOLIS BiORAD选择用于HIV和HBsAg的反应性和非反应性血液样品。 RDT的敏感性由EPI Info 6.04DFR(CDC,Atlanta,USA)计算。结果对血液供血中HIV检测HIV的敏感性为50.9%,对于Biosynex Exactioco Pro HIV,81.8%,MEDIFF HIV 1&amp的81.8%; 2血清/ Sang总盒与COBAS 6000 E601相比。与半自动ELISA BIO-RAD相比,Salere确定的敏感性为HIV检测为65.6%。与检测HBsAg检测的ELISA检测相比Biosynex免疫Quick HBsAg的敏感性为78.0%。检测HIV和HBsAg的所有RDT的特异性为100%。结论Shere确定HIV-1/2,MEDIFF HIV 1& 2血清/ SANG总卡带,BIOSYNEX BERCORO PRO HIV,BIOSYNEX IMMUNOQUICK HBSAG不建议确定捐赠者是否有资格赋予血液,因为它们对艾滋病毒检测的敏感性低敏感性加蓬献血者抗体和HBsAg。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号