首页> 外文期刊>Journal of Conservative Dentistry >Comparative evaluation of three methods to measure working length - Manual tactile sensation, digital radiograph, and multidetector computed tomography: An in vitro study
【24h】

Comparative evaluation of three methods to measure working length - Manual tactile sensation, digital radiograph, and multidetector computed tomography: An in vitro study

机译:三种测量工作长度的方法的比较评估-手动触感,数字射线照相和多探测器计算机断层扫描:一项体外研究

获取原文
           

摘要

Aim: Compare the measurement of working length with three different methods manual tactile sensation, digital radiography and Mutidetector computed tomography(MDCT). Materials and Method: 40 human premolar extracted for orthodontic purpose were selected. Teeth were store in sodium chloride (0.9%) during the study. Access cavity was prepared and canal patency was seen with no 10 file in each tooth. Manually no 15 K file was inserted from access cavity until the tip was visible at the foramen, a silicon stopper was adjusted to the corresponding buccal cusp tip and the root canal length was measured. After that in each tooth with no-15 K file inserted from access cavity with stop at tip of buccal cusp until tip appear at foramen and x-ray was taken with digital radiograph (RVG,Satelac) and canal length was measured. After that all teeth are mounted in wax block,MDCT scan was done and in the scan images of teeth, root canal length is measured from buccal cusp tip to root end. After taking measurement of working length with all three methods and the data was stastically analyzed with One Way Analysis of variance (ANOVA) followed by Turkey's Test. Results: ANOVA and turkeys test showed that there was no significant difference in the measurements by the three procedures (p>0.05). Conclusion: Working length measurement with MDCT scan and other two conventional methods does not show significant difference in measurement. Use of newer 3D imaging technique is useful in root canal treatment for measuring working length.
机译:目的:用三种不同的方法来比较工作长度的测量方法:手动触感,数字射线照相和Mutidetector计算机断层扫描(MDCT)。材料和方法:选择40颗用于正畸目的的人类前磨牙。在研究期间,牙齿被储存在氯化钠(0.9%)中。准备进入腔,并观察到每根牙齿没有10锉的通畅性。手动从进入腔插入15 K锉刀,直到在孔眼可见尖端为止,将硅塞调整至相应的颊尖尖端,并测量根管长度。之后,在每颗牙齿中,没有15 K锉刀从进入腔插入,在颊瓣尖的尖端停止,直到尖端出现在孔中,并用数字X射线照片(RVG,Satelac)拍摄X射线并测量管长。将所有牙齿固定在蜡块中之后,进行MDCT扫描,并在牙齿的扫描图像中测量从颊尖尖到根端的根管长度。在使用所有三种方法测量工作长度之后,使用单向方差分析(ANOVA)进行了统计分析,然后进行了土耳其检验。结果:方差分析和火鸡测试显示,三种方法的测量值无显着差异(p> 0.05)。结论:使用MDCT扫描和其他两种常规方法进行的工作长度测量在测量上没有显着差异。使用更新的3D成像技术可在根管治疗中测量工作长度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号