首页> 外文期刊>Journal of cardiovascular magnetic resonance : >Fast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectory
【24h】

Fast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectory

机译:使用径向轨迹通过CMR显微镜对小鼠进行快速回顾性触发的局部脉搏波速度测量

获取原文
   

获取外文期刊封面封底 >>

       

摘要

BackgroundThe aortic pulse-wave velocity (PWV) is an important indicator of cardiovascular risk. In recent studies MRI methods have been developed to measure this parameter noninvasively in mice. Present techniques require additional hardware for cardiac and respiratory gating. In this work a robust self-gated measurement of the local PWV in mice without the need of triggering probes is proposed.MethodsThe local PWV of 6-months-old wild-type C57BL/6J mice (n=6) was measured in the abdominal aorta with a retrospectively triggered radial Phase Contrast (PC) MR sequence using the flow-area (QA) method. A navigator signal was extracted from the CMR data of highly asymmetric radial projections with short repetition time (TR=3 ms) and post-processed with high-pass and low-pass filters for retrospective cardiac and respiratory gating. The self-gating signal was used for a reconstruction of high-resolution Cine frames of the aortic motion. To assess the local PWV the volume flow Q and the cross-sectional area A of the aorta were determined. The results were compared with the values measured with a triggered Cartesian and an undersampled triggered radial PC-Cine sequence.ResultsIn all examined animals a self-gating signal could be extracted and used for retrospective breath-gating and PC-Cine reconstruction. With the non-triggered measurement PWV values of 2.3±0.2 m/s were determined. These values are in agreement with those measured with the triggered Cartesian (2.4±0.2 m/s) and the triggered radial (2.3±0.2 m/s) measurement. Due to the strong robustness of the radial trajectory against undersampling an acceleration of more than two relative to the prospectively triggered Cartesian sampling could be achieved with the retrospective method.ConclusionWith the radial flow-encoding sequence the extraction of a self-gating signal is feasible. The retrospective method enables a robust and fast measurement of the local PWV without the need of additional trigger hardware.
机译:背景主动脉脉搏波速度(PWV)是心血管风险的重要指标。在最近的研究中,已经开发出MRI方法来无创地在小鼠中测量该参数。当前的技术需要用于心脏和呼吸门控的附加硬件。在这项工作中,提出了一种无需触发探针即可对小鼠局部PWV进行鲁棒的自门控测量的方法。方法在腹部测量6个月大的野生型C57BL / 6J小鼠(n = 6)的局部PWV。使用流面积(QA)方法回顾性触发径向相衬(PC)MR序列的主动脉。从具有短重复时间(TR = 3 ms)的高度非对称径向投影的CMR数据中提取导航信号,并用高通和低通滤波器进行后处理,以进行回顾性心脏和呼吸门控。自门控信号用于重建主动脉运动的高分辨率Cine帧。为了评估局部PWV,确定了主动脉的体积流量Q和横截面积A。将结果与通过触发笛卡尔和欠采样触发径向PC-Cine序列测量的值进行比较。结果在所有检查的动物中,可以提取自门控信号,并将其用于回顾性呼吸门控和PC-Cine重建。通过非触发测量,PWV值确定为2.3±0.2 m / s。这些值与通过触发的笛卡尔(2.4±0.2 m / s)和触发的径向(2.3±0.2 m / s)测量得到的值一致。由于径向轨迹对欠采样的强大鲁棒性,使用回顾性方法可以实现相对于预期触发的笛卡尔采样的两倍以上的加速度。结论利用径向流编码序列,自门控信号的提取是可行的。回顾性方法可实现对本地PWV的强大而快速的测量,而无需其他触发硬件。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号