...
首页> 外文期刊>Journal of Advances in Biology & Biotechnology >Sero-prevalence and Risk Factors for Hepatitis A Virus Infection among Pregnant Women at the Samandin Medical Center, Ouagadougou, Burkina Faso
【24h】

Sero-prevalence and Risk Factors for Hepatitis A Virus Infection among Pregnant Women at the Samandin Medical Center, Ouagadougou, Burkina Faso

机译:布基纳法索瓦加杜古萨曼丁医学中心孕妇的血清流行率和甲型肝炎病毒感染的危险因素

获取原文
           

摘要

Aims: This study determined prevalence and possible risk factors associated with HAV infection and compared Immunochromatography (IgG) rapid point of care test with standard ELISA test for diagnosis. Study Design: Cross sectional epidemiological survey. Place and duration of Study: The study was carried out at the Samandin Medical Center (Ouagadougou, Burkina Faso), from July 2017 to December 2017. Methodology: A total of 180 pregnant women were recruited at the Samandin Medical Center. Anti-HAV IgM and IgG detection tests were performed using AccuDiag? HAV ELISA kit (Calabasas, CA, USA) and SD BIOLINE HAV IgG/IgM Rapid Diagnostic Test (Gyeonggi-do, Korea). Results: IgG anti-HAV antibodies (AccuDiag Elisa) were found with a prevalence of 88.9% (160/180) and Anti-HAV IgM were 1.1% (2/180). Of the 160 AccuDiag HAV IgG positive samples, 44.4% (80/180) tested positive using SD BIOLINE Diagnostics HAV IgG. Regarding risk factors, 86.9% (86/99) of the IgG positive women were illiterate; 90.7% (39/43) lived mostly in peripheral areas; 89.2% (74/83) were household workers and 88.6% (93/105) used fountain water. Conclusion: Our results demonstrated poor agreement between the assays tested, which are consistent with previous reports demonstrating significant variability between HAV ELISA and RDT HAV. Moreover, the detection of HAV specific IgM antibodies in two asymptomatic pregnant women signaled the current circulation of HAV in this area.
机译:目的:本研究确定了与HAV感染相关的患病率和可能的危险因素,并将免疫层析(IgG)快速护理点测试与标准ELISA测试进行了比较以进行诊断。研究设计:横断面流行病学调查。研究的地点和时间:该研究于2017年7月至2017年12月在萨曼丁医学中心(布基纳法索瓦加杜古)进行。方法:在萨曼丁医学中心招募了180名孕妇。使用AccuDiag?进行抗HAV IgM和IgG检测。 HAV ELISA试剂盒(美国加利福尼亚州卡拉巴萨)和SD BIOLINE HAV IgG / IgM快速诊断测试(韩国京畿道)。结果:发现IgG抗HAV抗体(AccuDiag Elisa)的患病率为88.9%(160/180),抗HAV IgM的患病率为1.1%(2/180)。在160个AccuDiag HAV IgG阳性样品中,有44.4%(80/180)使用SD BIOLINE Diagnostics HAV IgG检测为阳性。关于危险因素,IgG阳性妇女中有86.9%(86/99)为文盲; 90.7%(39/43)的人主要居住在外围地区; 89.2%(74/83)是家庭工人,88.6%(93/105)用过喷泉水。结论:我们的结果表明,所测试的检测方法之间的一致性差,这与以前的报道一致,表明HAV ELISA和RDT HAV之间存在显着差异。此外,在两名无症状孕妇中检测到HAV特异性IgM抗体,标志着该地区当前HAV的流行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号