A T-stub connection with high-strength bolts under tensile force is affected by prying action force and the contact force, among others, between members. If a design equation that does not consider such prying action force and contact force between members is not proposed, the T-stub under tensile force is liable to be fractured under a strength lower than the estimated design strength. To prevent this, many studies have proposed contact force estimation equations between members as well as the prying action force of the T-stub connection with high-strength bolts. However, no design equations based on such research have been proposed in South Korea. Therefore, this study aims to propose an estimation model for more accurate prying action force and contact force, and to improve on previously proposed estimation models by implementing three-dimensional, nonlinear finite element analysis.
机译:在拉力下使用高强度螺栓的T型短管连接受到构件之间的撬作用力和接触力等的影响。如果未提出不考虑这种撬动力和构件之间的接触力的设计方程式,则在拉力作用下的T型短管容易在低于估计设计强度的强度下断裂。为了防止这种情况,许多研究提出了构件之间的接触力估算方程以及高强度螺栓的T型连接的撬动力。但是,韩国尚未提出基于此类研究的设计方程式。因此,本研究旨在提出一种更精确的撬动作用力和接触力的估计模型,并通过实施三维非线性有限元分析来改进先前提出的估计模型。