Evaluation of a single‐scan protocol for radiochromic film dosimetry

机译:评估变色胶片剂量法的单扫描协议

获取原文
           

摘要

The purpose of this study was to evaluate a single-scan protocol using Gafchromic EBT3 film (EBT3) by comparing it with the commonly used 24-hr measurement protocol for radiochromic film dosimetry. Radiochromic film is generally scanned 24 hr after film exposure (24-hr protocol). The single-scan protocol enables measurement results within a short time using only the verification film, one calibration film, and unirradiated film. The single-scan protocol was scanned 30 min after film irradiation. The EBT3 calibration curves were obtained with the multichannel film dosimetry method. The dose verifications for each protocol were performed with the step pattern, pyramid pattern, and clinical treatment plans for intensity-modulated radiation therapy (IMRT). The absolute dose distributions for each protocol were compared with those calculated by the treatment planning system (TPS) using gamma evaluation at 3% and 3 mm. The dose distribution for the single-scan protocol was within 2% of the 24-hr protocol dose distribution. For the step pattern, the absolute dose discrepancies between the TPS for the single-scan and 24-hr protocols were 2.0 ± 1.8 cGy and 1.4 ± 1.2 cGy at the dose plateau, respectively. The pass rates were 96.0% for the single-scan protocol and 95.9% for the 24-hr protocol. Similarly, the dose discrepancies for the pyramid pattern were 3.6 ± 3.5 cGy and 2.9 ± 3.3 cGy , respectively, while the pass rates for the pyramid pattern were 95.3% and 96.4%, respectively. The average pass rates for the four IMRT plans were 96.7 % ± 1.8 % for the single-scan protocol and 97.3 % ± 1.4 % for the 24-hr protocol. Thus, the single-scan protocol measurement is useful for dose verification of IMRT, based on its accuracy and efficiency.PACS number: 87.55.Qr
机译:这项研究的目的是通过将Gafchromic EBT3胶片(EBT3)与用于放射致变色胶片剂量测定的常用24小时测量协议进行比较来评估单扫描协议。通常在胶片曝光后24小时(24小时规程)扫描放射变色胶片。单扫描协议仅使用验证膜,一个校准膜和未辐照膜即可在短时间内实现测量结果。胶片照射后30分钟扫描一次扫描协议。 EBT3校准曲线是通过多通道薄膜剂量法获得的。每种方案的剂量验证均采用强度调制放射治疗(IMRT)的步骤模式,金字塔模式和临床治疗计划进行。使用3%和3 mm的伽马评估,将每个方案的绝对剂量分布与通过治疗计划系统(TPS)计算的剂量进行比较。单次扫描方案的剂量分布在24小时方案剂量分布的2%以内。对于步进模式,单次扫描和24小时方案的TPS之间的绝对剂量差异在剂量平稳期分别为2.0±1.8 cGy和1.4±1.2 cGy。单次扫描方案的通过率为96.0%,24小时方案的通过率为95.9%。同样,金字塔图案的剂量差异分别为3.6±3.5 cGy和2.9±3.3 cGy,而金字塔图案的合格率分别为95.3%和96.4%。四个IMRT计划的平均通过率对于单扫描协议是96.7%±1.8%,对于24小时协议是97.3%±1.4%。因此,单次扫描协议测量基于其准确性和效率可用于IMRT剂量验证.PACS编号:87.55.Qr

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号