Comparison of Exercise Stress Testing with Dobutamine Stress Echocardiography and Exercise Technetium-99m Isonitrile Single Photon Emission Computerized Tomography for Diagnosis of Coronary Artery Disease

机译:多巴酚丁胺应力超声心动图与运动Tech 99m异腈单光子发射计算机断层扫描对冠状动脉疾病诊断的运动压力测试的比较

获取原文
           

摘要

To compare the value of exercise electrocardiography with dobutamine stress echocardiography and exercise technetium-99m isonitrile single-photon emission computed tomography for coronary artery disease, 70 patients with either suspected or proven coronary artery disease underwent dobutamine stress echocardiography, exercise technetium-99m isonitrile single-photon emission computed tomography (mibi-SPECT) and treadmill exercise electrocardiography (ECG). Dobutamine echocardiography and exercise mibiSPECT revealed a higher overall sensitivitiy than exercise testing (90 vs 57%, p0.001; 96 vs 57%, p0.001, respectively). Dobutamine stress echocardiography showed a higher specificity than both exercise mibi-SPECT and treadmill exercise electrocardiography (90 vs 71%, p>0.05; 90 and 62% p0.05, respectively) but the difference between dobutamine stress echocardiography and exercise mibi-SPECT was not statistically significant. Diagnostic accuracy of dobutamine stress echocardiography and exercise mibi-SPECT was higher than that of exercise testing (90 vs 59%, p0.001; 89 vs 59%, p0.001, re-spectively). Dobutamine stress echocardiography and exercise mibi-SPECT have superiority over exercise testing in the diagnosis of coronary artery disease and dobutamine stress echocardiography is an alternative for exercise mibi-SPECT.
机译:为了比较运动心电图与多巴酚丁胺负荷超声心动图和运动tech 99m异腈单光子发射计算机断层扫描对冠状动脉疾病的价值,对70名怀疑或确诊冠心病的患者进行了多巴酚丁胺负荷超声心动图,运动tech 99m异腈单光子发射计算机断层扫描(mibi-SPECT)和跑步机运动心电图(ECG)。多巴酚丁胺超声心动图和运动mibiSPECT显示总体敏感性高于运动测试(分别为90%vs. 57%,p0.001; 96%vs 57%,p0.001)。多巴酚丁胺应激超声心动图显示出比运动mibi-SPECT和跑步机运动心电图更高的特异性(分别为90%vs 71%,p> 0.05; 90%和62%p0.05),但是多巴酚丁胺应激超声心动图与运动mibi-SPECT之间的差异是没有统计学意义。多巴酚丁胺负荷超声心动图和运动mibi-SPECT的诊断准确性高于运动测试(分别为90%vs 59%,p0.001; 89%vs 59%,p0.001)。多巴酚丁胺应力超声心动图和运动mibi-SPECT在诊断冠状动脉疾病方面优于运动测试,多巴酚丁胺应力超声心动图是运动mibi-SPECT的替代方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号