首页> 外文期刊>Journal of advanced concrete technology >Strength of Beam-column Joint in Soft First Story RC Buildings Part 1: Experiment
【24h】

Strength of Beam-column Joint in Soft First Story RC Buildings Part 1: Experiment

机译:软第一层RC建筑中梁柱节点的强度第1部分:实验

获取原文
获取外文期刊封面目录资料

摘要

This study describes the strength of reinforced concrete (RC) beam-column joints in buildings with a soft first story. In such buildings, the sections of first-story columns are usually much larger than those of second-story columns to prevent story collapse. To investigate the strength of the beam-column joints, four specimens are constructed and the test is conducted with two types of joints: 1) the first-story column is extended toward the inside of the building (I-type joint) and 2) the first-story column is extended toward the outside of the building (O-type joint). The test parameters are the hoops in the beam-column joint, beam reinforcements, stirrups in the beam, and axial force. The beam longitudinal re-inforcements are effective to prevent the yielding of the beam reinforcements in both types of joint. Stirrups in beam and hoops in joint strengthen I- and O-type joints, respectively. The force-resistant mechanisms of these joints are different from those of usual beam-column joints because sign of the bending moment in the second-story column is the same as that of the first-story column. The failure modes of these joints are also different from those of the usual beam-column joints.
机译:这项研究描述了软建筑的钢筋混凝土(RC)梁柱节点的强度。在此类建筑物中,第一层专栏的部分通常比第二层专栏的部分大得多,以防止故事崩溃。为了研究梁柱节点的强度,构造了四个样本,并用两种类型的节点进行了测试:1)第一层柱向建筑物内部延伸(I型节点); 2)第一层柱向建筑物外部延伸(O型接头)。测试参数是梁柱连接处的箍,梁加强筋,梁中的箍筋和轴向力。梁的纵向钢筋有效地防止了两种类型的接头中的梁钢筋屈服。关节中的梁箍筋和箍箍分别增强了I型和O型关节。这些接头的抗力机理与通常的梁柱接头的抗力机理不同,因为第二层立柱的弯矩符号与第一层立柱的弯矩符号相同。这些接头的失效模式也不同于通常的梁柱接头。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号