首页> 外文期刊>Dental Press Journal of Orthodontics >Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study
【24h】

Influence of ligation method on friction resistance of lingual brackets with different second-order angulations: an in vitro study

机译:结扎方法对不同二阶角度舌托摩擦阻力的影响

获取原文

摘要

Objective: To evaluate stainless steel archwire static friction in active and passive self-ligating lingual and conventional brackets with second-order angulations. Methods: Two conventional lingual brackets for canines (STb light/Ormco; PSWb/Tecnident), and two self-ligating brackets, one active (In-Ovation L/GAC) and the other passive (3D/ Forestadent), were evaluated. A stainless steel archwire was used at 0?°, 3?° and 5?° angulations. Metal ligatures, conventional elastic ligatures, and low friction elastic ligatures were also tested. A universal testing machine applied friction between brackets and wires, simulating sliding mechanics, to produce 2-mm sliding at 3 mm/minute speed. Results: Two-way analysis of variance demonstrated a significant effect of the interaction between brackets and angulations ( p < 0.001). Tukey test indicated that the highest frictional resistance values were observed at 5?° angulation for In-Ovation L, PSWb bracket with non conventional ligature, and STb bracket with metal ligature. As for 3D, PSWb with conventional or metal ligatures, and STb brackets with non conventional ligature, showed significantly lower static frictional resistance with 0?° angulation. At 0?° angulation, STb brackets with metal ties, In-Ovation L brackets and 3D brackets had the lowest frictional resistance. Conclusions: As the angulation increased from 0?° to 3?°, static friction resistance increased. When angulation increased from 3?° to 5?°, static friction resistance increased or remained the same. Self-ligating 3D and In-Ovation L brackets, as well as conventional STb brackets, seem to be the best option when sliding mechanics is used to perform lingual orthodontic treatment.
机译:目的:评估带二阶角度的主动和被动自结扎舌头和传统托槽中的不锈钢弓丝静摩擦。方法:评估了两个传统的犬齿支架(STb light / Ormco; PSWb / Tecnident)和两个自结扎支架,一个是主动式(In-Ovation L / GAC),另一个是被动式(3D / Forestadent)。使用不锈钢弓丝,角度为0°,3°和5°。还测试了金属绑带,常规弹性绑带和低摩擦弹性绑带。一台万能试验机在支架和金属丝之间施加摩擦,模拟滑动机理,以3毫米/分钟的速度产生2毫米的滑动。结果:方差的双向分析表明方括号和角度之间的交互作用具有显着影响(p <0.001)。 Tukey试验表明,对于In-Ovation L,使用非常规绑扎的PSWb支架和使用金属绑扎的STb支架,在5°角时观察到最高的摩擦阻力值。对于3D,具有常规或金属绑扎的PSWb和具有非常规绑扎的STb托槽在0?°角度下表现出明显较低的静摩擦阻力。角度为0°时,带金属扎带的STb支架,In-Ovation L支架和3D支架的摩擦阻力最低。结论:随着角度从0°°增大到3°°,抗静摩擦性也增加。当角度从3°增加到5°时,静摩擦阻力增加或保持不变。当使用滑动力学进行舌正畸治疗时,自结扎3D和In-Ovation L托槽以及传统的STb托槽似乎是最佳选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号